1
/
/
10
PayPal, credit cards. Download editable-PDF and invoice in 1 second!
SN/T 3077.2-2012 English PDF (SNT3077.2-2012)
SN/T 3077.2-2012 English PDF (SNT3077.2-2012)
Normaalihinta
$185.00 USD
Normaalihinta
Alennushinta
$185.00 USD
Yksikköhinta
/
kohti
Toimituskulut lasketaan kassalla.
Noudon saatavuutta ei voitu ladata
Delivery: 3 seconds. Download true-PDF + Invoice.
Get Quotation: Click SN/T 3077.2-2012 (Self-service in 1-minute)
Historical versions (Master-website): SN/T 3077.2-2012
Preview True-PDF (Reload/Scroll-down if blank)
SN/T 3077.2-2012: Test method of flash point. Modified continuously closed cup tester
SN/T 3077.2-2012
SN
ENTRY-EXIT INSPECTION AND QUARANTINE INDUSTRY
STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA
Test method for flash point - Modified continuously closed
cup tester
ISSUED ON: MAY 07, 2012
IMPLEMENTED ON: NOVEMBER 16, 2012
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions ... 5
4 Method overview ... 5
5 Significance and use ... 6
6 Apparatus ... 6
7 Reagents and materials ... 8
8 Sampling ... 8
9 Quality control check ... 9
10 Instrument calibration ... 9
11 Test procedure ... 10
12 Calculation ... 11
13 Report ... 12
14 Precision and deviation ... 12
Appendix A (Normative) Instrument specifications ... 13
Appendix B (Informative) Liquids used for instrument calibration ... 15
Test method for flash point - Modified continuously closed
cup tester
1 Scope
This Part of SN/T 3077 specifies the determination method of flash point by modified
continuously closed cup tester.
Note: For the substance being tested, the flash point is not a constant physical and chemical
constant. It is related to the instrument design, instrument use conditions, test execution steps.
Therefore, the flash point can only be defined according to the standard test method. There is
no guarantee that the results measured by different methods or different test instruments have a
universally valid correlation.
This Part applies to the determination of the flash point of fuel oil, lubricating oil,
solvent oil, and other liquids; the measurement range is 35 °C ~ 225 °C.
Note: This Part can determine samples with flash points below 35 °C or above 225 °C, but the
precision has not been established.
If the flash point test method specified in the product specification required by the user
is not this method, neither this method nor any other method can replace the specified
method without comparative data and approval by the specification setter.
This Part involves certain hazardous materials, operations, and equipment, but does not
provide recommendations for all safety issues related to this. Therefore, it is necessary
to establish appropriate safety and protective measures and establish appropriate
operating procedures before using the standard. Special hazard warnings are shown in
7.2, 8.5, 10.1.2 warnings.
2 Normative references
The following documents are essential for the application of this document. For all
dated references, only the dated version applies to this document. For all undated
references, the latest version (including all amendments) applies to this document.
ASTM D93 Standard test methods for flash point by Pensky-Martens closed cup
tester
ASTM D4057 Standard practice for manual sampling of petroleum and petroleum
products
ASTM D4177 Standard practice for automatic sampling of petroleum and petroleum
products
ASTM D6450 Standard test method for flash point by continuously closed cup
(CCCFP) tester
ASTM D6708 Standard practice for statistical assessment and improvement of
expected agreement between two test methods that purport to measure the same
property of a material
ASTM E300 Standard practice for sampling industrial chemicals
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Flash point
The lowest temperature (corrected to 101.3 kPa pressure) at which the vapor of the
specimen ignites under the specified test conditions. In a closed test chamber, the
specimen is confirmed to have flashed when the instantaneous pressure increase
caused by the hot flame is not less than 20 kPa.
3.2
Dynamic
The state when the vapor on the specimen and the specimen have not reached
temperature equilibrium when the fire source is introduced.
4 Method overview
4.1 Set the test temperature to be not less than 18 °C lower than the expected flash point.
Inject 2.0 mL ± 0.2 mL of the specimen into the sample cup. The temperature of the
specimen and the sample cup is not less than (the same below) 18 °C lower than the
expected flash point; it can be cooled if necessary. Raise the sample cup and press it
tightly with the lid to achieve airtightness. At this time, the total volume of the test
chamber is 7.0 mL ± 0.3 mL.
4.2 After the test chamber is closed, the temperature difference between the specimen
and the lid shall be within 1 °C; it is heated at a uniform rate. A high-voltage arc of a
certain energy is discharged in the test chamber at specified intervals. After each
ignition, an indefinite amount of air (see Table 1) is introduced into the test chamber, to
provide the required oxygen for the next flash test. The pressure in the test chamber is
voltage arcs, a connecting pipe connected to the lid for pressure detection and air
introduction. It also requires an electronic device to control the temperature of the test
chamber and a digital display that can display the specimen temperature. The apparatus
and its main components are shown in Figures A.1 and A.2:
- Test chamber: The test chamber consists of a sample cup and a temperature-
controlled lid with a total volume of 7.0 mL ± 0.3 mL. The metal contact between
the lid and the sample cup is to ensure good heat conduction; the incomplete seal
is to ensure that the test chamber is at ambient atmospheric pressure during the test.
Its dimensions are shown in Figure A.2. When the temperature rises, the pressure
in the test chamber will be detected. Excessive sealing will cause the pressure
increase caused by the temperature and vapor pressure of the specimen to be higher
than the atmospheric pressure. Poor heat conduction will cause a large difference
in temperature between the specimen and the lid.
- Sample cup: The sample cup can be made of nickel-plated aluminum or other
materials with similar thermal conductivity. The sample cup is a cup that forms a
seal after closing and can accept air injection test chamber function. Its total volume
is 7.0 mL ± 0.3 mL and can accommodate 2.0 mL ± 0.2 mL of specimen. Its
dimensions and requirements are shown in Figure A.2.
- Specimen temperature sensor: The specimen temperature sensor (see Figure A.1)
is a stainless steel thermocouple with a diameter of 1 mm (NiCr-Ni or similar) and
a response time of t(90) = 3 s. Its insertion depth into the specimen shall be not less
than 2 mm; the temperature sensing sensitivity is 0.1 °C; the accuracy is ± 0.2 °C;
it is best to connect a temperature display.
- Magnetic stirring: The instrument must be able to stir the sample. The sample cup
is equipped with a rotating magnet, which can rotate a small stirring magnet placed
in the sample cup containing the specimen. The diameter of the stirring magnet is
3.0 mm ± 0.2 mm and the length is 12 mm ± 1 mm. The speed of the driving magnet
is 250 r/min ~ 270 r/min.
- Air introduction device: The instrument must be able to introduce air immediately
after each flash test. A small membrane air compressor generates a short air pulse
and introduces air into the pressure sensor through the T-type inlet in the connecting
pipe. The amount of air introduced depends on the sample temperature (see Table
1), 0.5 mL ~ 2.0 mL.
- Temperature regulation device: During the test, the temperature of the test chamber
is regulated by electric heating and cooling of the lid. The temperature control
accuracy is ±0.2 °C.
- High-voltage arc: Use high-voltage arc to ignite flammable vapors. The energy of
each arc shall be 1.3 J ± 0.3 J (1.3 ws ± 0.3 ws)/arc; the arc time shall be within 19
ms ± 2 ms.
Note: When the specimen contains low-flash point substances or the flash point of
the specimen is lower than the initial temperature, saturated vapor may be
generated in the test chamber. Therefore, when the instrument is set up, it shall be
able to enable that, after the test chamber is closed and before reaching the initial
temperature, the arc shall be pre-set to an interval of 5 °C, when the temperature of
the lid and the sample cup is in equilibrium.
- Flash point pressure test sensor: The flash pressure test sensor shall be connected
to the connecting pipe in the lid, which has an operating range of 80 kPa ~ 177 kPa,
a minimum resolution of 0.1 kPa, a minimum accuracy of ± 0.5 kPa. It can measure
an instantaneous pressure increase of at least 20 kPa above atmospheric pressure
within 100 ms.
- Pipette or syringe: 2.0 mL ± 0.2 mL of specimen can be transferred using a pipette
or syringe that meets the accuracy requirements.
7 Reagents and materials
7.1 Reagents and purity
Purity requirements for chemicals used refer to Table B.1. Unless otherwise specified,
analytical grade reagents shall be used. Other grades of reagents may be used when the
purity of the reagents used does not affect the accuracy of the measurement.
7.2 Cleaning solvents
Only non-corrosive solvents such as toluene and acetone can be used to clean the
sample cup and lid.
Warning: Anisole, n-dodecane, styrene, acetone and many solvents are flammable and
harmful to health. Dispose of solutions and waste in accordance with relevant regulations.
8 Sampling
8.1 Take at least 50 mL of specimen from the container according to the requirements
of standards ASTM D4057, ASTM D4177 or ASTM E300; place it in a clean, well-
sealed container; store it at low temperature.
8.2 Specimens should not be stored in breathable containers such as plastic bottles for
long periods of time, because volatile substances can diffuse through the container walls.
Specimens stored in poorly sealed containers shall be discarded and resampling shall
be carried out.
8.3 Measures shall be taken to avoid the loss of volatile substances, so as not to obtain
a higher flash point. Do not open the container unless it is necessary. Do not transfer
10.1.1 After completing the quality control check in Chapter 9, the pressure sensor can
be calibrated if necessary. Calibrate the pressure sensor using the ambient atmospheric
pressure as a reference.
10.1.2 If the displayed atmospheric pressure is different from the ambient atmospheric
pressure, adjust the sensor control until the appropriate reading is observed. The
ambient atmospheric pressure is the pressure at the actual location of the tester during
the test.
Warning: Many metal barometers used in weather stations and airports are pre-
calibrated to sea level. These barometers do not require instrument calibration.
10.2 Temperature sensor
After completing the quality control checks in Chapter 9, the pressure sensor may be
calibrated, if necessary, by checking the sample temperature.
11 Test procedure
11.1 Before testing, thoroughly clean the lid, arc probe, sample cup; dry them to ensure
that any solvent used for instrument cleaning is removed. If the expected flash point of
the specimen is 15 °C higher than the flash point of the previous sample, heat the empty,
dry sample cup with lid to a temperature at least 30 °C higher than the expected flash
point of the new specimen.
Note: Drying and heating the sample cup will eliminate possible cross-contamination from
residual vapors.
11.2 Expected flash point: Set the initial ignition temperature to be at least 18 °C lower
than the expected flash point and the final temperature to be higher than the expected
temperature. Unknown expected flash point: If the expected flash point of the test
substance is unknown, set the initial ignition temperature to 10 °C and test as follows.
The flash point obtained is an approximate value. When the new specimen is tested
again by the standard method, this value can be used as the expected flash point of the
specimen.
11.3 Set the heating rate: 2.5 °C/min ± 0.3 °C/min.
11.4 Set the ignition frequency: 5 °C.
11.5 Set the air introduction volume: Set according to Table 1.
11.6 Set the flash point detection pressure threshold: 20 kPa.
11.7 Start the test according to the test steps. Adjust the temperature of the lid to the
initial ignition temperature. When the instrument indicates that the initial ignition
temperature has been reached, prepare to inject 2.0 mL ± 0.2 mL of specimen.
11.8 The temperature of the sealed specimen and sample cup shall be at least 18 °C
lower than the expected flash point. Cool if necessary. Shake the specimen well before
opening the sample container. Use pipette or syringe to take 2.0 mL ± 0.2 mL of
specimen; immediately seal the sample container. Transfer 2.0 mL ± 0.2 mL of
specimen to the sample cup.
11.9 Place a stirring magnet in the sample cup, to ensure that the specimen is mixed
well.
11.10 Place the sample cup in the sample test cup holder and start the test procedure.
11.11 If a flash point is detected while the sample cup and lid are equilibrating, stop the
test and discard the result. Retest with a new specimen. The initial ignition temperature
shall be at least 18 °C lower than the detected flash temperature.
11.12 When the oven temperature and the specimen temperature are within 1 °C of each
other, start the actual measurement of the flash point. Set the ignition frequency to 1 °C.
Heat the lid at the set heating rate.
11.13 Stop the measurement after the flash point is measured or when the final
temperature is reached without flashing. When the flash point is more than 26 °C above
the starting temperature or within 10 °C above the starting temperature, treat the
measurement result as an approximate result and repeat the measurement with a new
specimen. Adjust the expected flash point temperature to a temperature close to the
result. Set the starting temperature to 18 °C below the expected flash point.
11.14 Record the flash point temperature of the specimen, as the uncorrected flash point
temperature. If no flash point is detected within the test temperature range, record the
flash point above the end temperature.
11.15 After the test, wait for the sample cup to cool to below 50 °C and remove it safely.
12 Calculation
Observe and record...
Get Quotation: Click SN/T 3077.2-2012 (Self-service in 1-minute)
Historical versions (Master-website): SN/T 3077.2-2012
Preview True-PDF (Reload/Scroll-down if blank)
SN/T 3077.2-2012: Test method of flash point. Modified continuously closed cup tester
SN/T 3077.2-2012
SN
ENTRY-EXIT INSPECTION AND QUARANTINE INDUSTRY
STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA
Test method for flash point - Modified continuously closed
cup tester
ISSUED ON: MAY 07, 2012
IMPLEMENTED ON: NOVEMBER 16, 2012
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions ... 5
4 Method overview ... 5
5 Significance and use ... 6
6 Apparatus ... 6
7 Reagents and materials ... 8
8 Sampling ... 8
9 Quality control check ... 9
10 Instrument calibration ... 9
11 Test procedure ... 10
12 Calculation ... 11
13 Report ... 12
14 Precision and deviation ... 12
Appendix A (Normative) Instrument specifications ... 13
Appendix B (Informative) Liquids used for instrument calibration ... 15
Test method for flash point - Modified continuously closed
cup tester
1 Scope
This Part of SN/T 3077 specifies the determination method of flash point by modified
continuously closed cup tester.
Note: For the substance being tested, the flash point is not a constant physical and chemical
constant. It is related to the instrument design, instrument use conditions, test execution steps.
Therefore, the flash point can only be defined according to the standard test method. There is
no guarantee that the results measured by different methods or different test instruments have a
universally valid correlation.
This Part applies to the determination of the flash point of fuel oil, lubricating oil,
solvent oil, and other liquids; the measurement range is 35 °C ~ 225 °C.
Note: This Part can determine samples with flash points below 35 °C or above 225 °C, but the
precision has not been established.
If the flash point test method specified in the product specification required by the user
is not this method, neither this method nor any other method can replace the specified
method without comparative data and approval by the specification setter.
This Part involves certain hazardous materials, operations, and equipment, but does not
provide recommendations for all safety issues related to this. Therefore, it is necessary
to establish appropriate safety and protective measures and establish appropriate
operating procedures before using the standard. Special hazard warnings are shown in
7.2, 8.5, 10.1.2 warnings.
2 Normative references
The following documents are essential for the application of this document. For all
dated references, only the dated version applies to this document. For all undated
references, the latest version (including all amendments) applies to this document.
ASTM D93 Standard test methods for flash point by Pensky-Martens closed cup
tester
ASTM D4057 Standard practice for manual sampling of petroleum and petroleum
products
ASTM D4177 Standard practice for automatic sampling of petroleum and petroleum
products
ASTM D6450 Standard test method for flash point by continuously closed cup
(CCCFP) tester
ASTM D6708 Standard practice for statistical assessment and improvement of
expected agreement between two test methods that purport to measure the same
property of a material
ASTM E300 Standard practice for sampling industrial chemicals
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Flash point
The lowest temperature (corrected to 101.3 kPa pressure) at which the vapor of the
specimen ignites under the specified test conditions. In a closed test chamber, the
specimen is confirmed to have flashed when the instantaneous pressure increase
caused by the hot flame is not less than 20 kPa.
3.2
Dynamic
The state when the vapor on the specimen and the specimen have not reached
temperature equilibrium when the fire source is introduced.
4 Method overview
4.1 Set the test temperature to be not less than 18 °C lower than the expected flash point.
Inject 2.0 mL ± 0.2 mL of the specimen into the sample cup. The temperature of the
specimen and the sample cup is not less than (the same below) 18 °C lower than the
expected flash point; it can be cooled if necessary. Raise the sample cup and press it
tightly with the lid to achieve airtightness. At this time, the total volume of the test
chamber is 7.0 mL ± 0.3 mL.
4.2 After the test chamber is closed, the temperature difference between the specimen
and the lid shall be within 1 °C; it is heated at a uniform rate. A high-voltage arc of a
certain energy is discharged in the test chamber at specified intervals. After each
ignition, an indefinite amount of air (see Table 1) is introduced into the test chamber, to
provide the required oxygen for the next flash test. The pressure in the test chamber is
voltage arcs, a connecting pipe connected to the lid for pressure detection and air
introduction. It also requires an electronic device to control the temperature of the test
chamber and a digital display that can display the specimen temperature. The apparatus
and its main components are shown in Figures A.1 and A.2:
- Test chamber: The test chamber consists of a sample cup and a temperature-
controlled lid with a total volume of 7.0 mL ± 0.3 mL. The metal contact between
the lid and the sample cup is to ensure good heat conduction; the incomplete seal
is to ensure that the test chamber is at ambient atmospheric pressure during the test.
Its dimensions are shown in Figure A.2. When the temperature rises, the pressure
in the test chamber will be detected. Excessive sealing will cause the pressure
increase caused by the temperature and vapor pressure of the specimen to be higher
than the atmospheric pressure. Poor heat conduction will cause a large difference
in temperature between the specimen and the lid.
- Sample cup: The sample cup can be made of nickel-plated aluminum or other
materials with similar thermal conductivity. The sample cup is a cup that forms a
seal after closing and can accept air injection test chamber function. Its total volume
is 7.0 mL ± 0.3 mL and can accommodate 2.0 mL ± 0.2 mL of specimen. Its
dimensions and requirements are shown in Figure A.2.
- Specimen temperature sensor: The specimen temperature sensor (see Figure A.1)
is a stainless steel thermocouple with a diameter of 1 mm (NiCr-Ni or similar) and
a response time of t(90) = 3 s. Its insertion depth into the specimen shall be not less
than 2 mm; the temperature sensing sensitivity is 0.1 °C; the accuracy is ± 0.2 °C;
it is best to connect a temperature display.
- Magnetic stirring: The instrument must be able to stir the sample. The sample cup
is equipped with a rotating magnet, which can rotate a small stirring magnet placed
in the sample cup containing the specimen. The diameter of the stirring magnet is
3.0 mm ± 0.2 mm and the length is 12 mm ± 1 mm. The speed of the driving magnet
is 250 r/min ~ 270 r/min.
- Air introduction device: The instrument must be able to introduce air immediately
after each flash test. A small membrane air compressor generates a short air pulse
and introduces air into the pressure sensor through the T-type inlet in the connecting
pipe. The amount of air introduced depends on the sample temperature (see Table
1), 0.5 mL ~ 2.0 mL.
- Temperature regulation device: During the test, the temperature of the test chamber
is regulated by electric heating and cooling of the lid. The temperature control
accuracy is ±0.2 °C.
- High-voltage arc: Use high-voltage arc to ignite flammable vapors. The energy of
each arc shall be 1.3 J ± 0.3 J (1.3 ws ± 0.3 ws)/arc; the arc time shall be within 19
ms ± 2 ms.
Note: When the specimen contains low-flash point substances or the flash point of
the specimen is lower than the initial temperature, saturated vapor may be
generated in the test chamber. Therefore, when the instrument is set up, it shall be
able to enable that, after the test chamber is closed and before reaching the initial
temperature, the arc shall be pre-set to an interval of 5 °C, when the temperature of
the lid and the sample cup is in equilibrium.
- Flash point pressure test sensor: The flash pressure test sensor shall be connected
to the connecting pipe in the lid, which has an operating range of 80 kPa ~ 177 kPa,
a minimum resolution of 0.1 kPa, a minimum accuracy of ± 0.5 kPa. It can measure
an instantaneous pressure increase of at least 20 kPa above atmospheric pressure
within 100 ms.
- Pipette or syringe: 2.0 mL ± 0.2 mL of specimen can be transferred using a pipette
or syringe that meets the accuracy requirements.
7 Reagents and materials
7.1 Reagents and purity
Purity requirements for chemicals used refer to Table B.1. Unless otherwise specified,
analytical grade reagents shall be used. Other grades of reagents may be used when the
purity of the reagents used does not affect the accuracy of the measurement.
7.2 Cleaning solvents
Only non-corrosive solvents such as toluene and acetone can be used to clean the
sample cup and lid.
Warning: Anisole, n-dodecane, styrene, acetone and many solvents are flammable and
harmful to health. Dispose of solutions and waste in accordance with relevant regulations.
8 Sampling
8.1 Take at least 50 mL of specimen from the container according to the requirements
of standards ASTM D4057, ASTM D4177 or ASTM E300; place it in a clean, well-
sealed container; store it at low temperature.
8.2 Specimens should not be stored in breathable containers such as plastic bottles for
long periods of time, because volatile substances can diffuse through the container walls.
Specimens stored in poorly sealed containers shall be discarded and resampling shall
be carried out.
8.3 Measures shall be taken to avoid the loss of volatile substances, so as not to obtain
a higher flash point. Do not open the container unless it is necessary. Do not transfer
10.1.1 After completing the quality control check in Chapter 9, the pressure sensor can
be calibrated if necessary. Calibrate the pressure sensor using the ambient atmospheric
pressure as a reference.
10.1.2 If the displayed atmospheric pressure is different from the ambient atmospheric
pressure, adjust the sensor control until the appropriate reading is observed. The
ambient atmospheric pressure is the pressure at the actual location of the tester during
the test.
Warning: Many metal barometers used in weather stations and airports are pre-
calibrated to sea level. These barometers do not require instrument calibration.
10.2 Temperature sensor
After completing the quality control checks in Chapter 9, the pressure sensor may be
calibrated, if necessary, by checking the sample temperature.
11 Test procedure
11.1 Before testing, thoroughly clean the lid, arc probe, sample cup; dry them to ensure
that any solvent used for instrument cleaning is removed. If the expected flash point of
the specimen is 15 °C higher than the flash point of the previous sample, heat the empty,
dry sample cup with lid to a temperature at least 30 °C higher than the expected flash
point of the new specimen.
Note: Drying and heating the sample cup will eliminate possible cross-contamination from
residual vapors.
11.2 Expected flash point: Set the initial ignition temperature to be at least 18 °C lower
than the expected flash point and the final temperature to be higher than the expected
temperature. Unknown expected flash point: If the expected flash point of the test
substance is unknown, set the initial ignition temperature to 10 °C and test as follows.
The flash point obtained is an approximate value. When the new specimen is tested
again by the standard method, this value can be used as the expected flash point of the
specimen.
11.3 Set the heating rate: 2.5 °C/min ± 0.3 °C/min.
11.4 Set the ignition frequency: 5 °C.
11.5 Set the air introduction volume: Set according to Table 1.
11.6 Set the flash point detection pressure threshold: 20 kPa.
11.7 Start the test according to the test steps. Adjust the temperature of the lid to the
initial ignition temperature. When the instrument indicates that the initial ignition
temperature has been reached, prepare to inject 2.0 mL ± 0.2 mL of specimen.
11.8 The temperature of the sealed specimen and sample cup shall be at least 18 °C
lower than the expected flash point. Cool if necessary. Shake the specimen well before
opening the sample container. Use pipette or syringe to take 2.0 mL ± 0.2 mL of
specimen; immediately seal the sample container. Transfer 2.0 mL ± 0.2 mL of
specimen to the sample cup.
11.9 Place a stirring magnet in the sample cup, to ensure that the specimen is mixed
well.
11.10 Place the sample cup in the sample test cup holder and start the test procedure.
11.11 If a flash point is detected while the sample cup and lid are equilibrating, stop the
test and discard the result. Retest with a new specimen. The initial ignition temperature
shall be at least 18 °C lower than the detected flash temperature.
11.12 When the oven temperature and the specimen temperature are within 1 °C of each
other, start the actual measurement of the flash point. Set the ignition frequency to 1 °C.
Heat the lid at the set heating rate.
11.13 Stop the measurement after the flash point is measured or when the final
temperature is reached without flashing. When the flash point is more than 26 °C above
the starting temperature or within 10 °C above the starting temperature, treat the
measurement result as an approximate result and repeat the measurement with a new
specimen. Adjust the expected flash point temperature to a temperature close to the
result. Set the starting temperature to 18 °C below the expected flash point.
11.14 Record the flash point temperature of the specimen, as the uncorrected flash point
temperature. If no flash point is detected within the test temperature range, record the
flash point above the end temperature.
11.15 After the test, wait for the sample cup to cool to below 50 °C and remove it safely.
12 Calculation
Observe and record...
Share









