Skip to product information
1 of 7

PayPal, credit cards. Download editable-PDF and invoice in 1 second!

GB 22794-2008 English PDF (GB22794-2008)

GB 22794-2008 English PDF (GB22794-2008)

Regular price $160.00 USD
Regular price Sale price $160.00 USD
Sale Sold out
Shipping calculated at checkout.
Delivery: 3 seconds. Download true-PDF + Invoice.Newer version: (Replacing this standard) GB/T 22794-2017
Get QUOTATION in 1-minute: Click GB 22794-2008
Historical versions: GB 22794-2008
Preview True-PDF (Reload/Scroll if blank)

GB 22794-2008: [GB/T 22794-2008] Type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (Type B RCCBs and Type B RCBOs)
GB 22794-2008
Type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (Type B RCCBs and Type B RCBOs)
ICS 29.120.50
K31
National Standards of People's Republic of China
GB 22794-2008/IEC 62423.2007
Household and similar purposes without overcurrent protection and
B residual current operated circuit breaker
(Type B and Type B RCCB RCBO)
(IEC 62423.2007, IDT)
Published 2008-12-30
2010-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China issued
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 Scope 1
2 Normative References 1
Terms and definitions 1 3
4 Category 2
5 Characteristics 2
6 3 logo and other product information
7 using standard operating conditions and installation 3
The structure and operation of claims 3 8
9 Test 4
Annex A (normative) B type RCCB compliance verification number of samples and test procedures 12
Annex B (normative) B type RCBO compliance verification number of samples and test procedures 14
Annex C (normative) routine experimentation 16
Reference 17
GB 22794-2008/IEC 62423.2007
Foreword
This standard Chapter 5, Chapter 6, Section 8 and Chapter 9 is mandatory, the rest are recommended.
This is equivalent to using the standard IEC 62423.2007 "without household and similar purposes and B residual current operated overcurrent protection broken
A road (B and B type RCCB RCBO) "(first edition) (English).
This standard is technically and IEC 62423.2007 is consistent, only made editorial changes or bug fixes to the following text.
--- deleted international standards foreword, preface to increase the national standards;
--- decimal symbol used in the preparation according to the requirements of national standards has been modified;
--- "IEC 60479-1", "IEC 60479-2", "IEC 61008-1.1996", "IEC 61009-1.1996" was changed to "GB/T 13870.1",
"GB/T 13870.2", "GB 16916.1-2003", "GB 16917.1-2003";
--- numbering of the references;
--- 3.1 The following review will be required to supplement the comments;
3.2 --- following functions, to cancel the "pulsating DC residual current" trip function that has been A residual current device
There, the following should not appear in the original error;
--- Table header and row 1 column 1 of 4, to modify the "residual current (IΔ) is equal to the following values are not time-division driving time and off time
Standard value ", IEC mistaken as the original" residual current (IΔ) ";
--- Table 2, line 4 and the second column, IEC text missing residual operating current value is not "IΔn" at 1000Hz, the root standard adoption
According to IEC 60755/T R.2008 "General requirements for residual current operated protective devices" were added;
After the footnote to Table 2 --- tables required by GB T/1.1 bets placed behind the table, IEC original table 2 is placed in Notes to Table footnotes.
This standard Annex A, Annex B and Annex C is normative.
The standard proposed by China Electrical Equipment Industrial Association.
The low-voltage electrical standard by the National Standardization Technical Committee (SAC/TC189) centralized.
This standard is drafted by. Shanghai Electrical Apparatus Research Institute (Group) Co., Ltd.
Participated in the drafting of this standard. Zhejiang Chint Electric Co., Ltd. People Electric Group Co., Ltd., Shi Naide Electric (China) Investment
Limited resources, Siemens Circuit Protection Systems Ltd., Beijing ABB Low Voltage Electric Co., Ltd., West Germany Electric Co., Ltd., Universal
Group Limited.
The main drafters of this standard. Zhou Gang plot, Chen Ying, Liu Jinyan.
Participate drafters of this standard. Wang Xianfeng, high Bunraku, Zhou Lei, Xiong Tao, Yang Wenguang, Huang Rongrong, Li Lifang.
GB 22794-2008/IEC 62423.2007
introduction
According to GB 16916.1 and GB 16917.1 design RCCB and RCBO should be applicable to most situations, however, the use of the device
New electronic technologies may have a specific residual current GB 16916.1 and GB 16917.1 can not be covered.
This standard includes a definition of the type B and type B RCCB RCBO relates to a specific case, the supplementary technical requirements and testing.
RCCB type B should be tested first by GB 16916.1, B RCBO type test press GB 16917.1.
After completion of the test, or the predetermined GB 16916.1 GB 16917.1, should additional tests specified in this standard in order to meet the present description
Standards (see Appendix A, respectively, or Appendix B).
RCCB type B or type B compliance verification RCBO the applicable test procedures and submitted to the number of samples or attached in Appendix A, respectively
Record B.
Smoothing the DC current is unlikely to occur in a single phase power supply with the neutral line. Nevertheless, even if the occurrence of residual smooth direct current,
A three-pole or four-pole residual current circuit breaker, as long as the manufacturer states that the device may be used for single-phase applications.
GB 22794-2008/IEC 62423.2007
Household and similar purposes without overcurrent protection and
B residual current operated circuit breaker
(Type B and Type B RCCB RCBO)
Range 1
GB 16916.1 and scope of GB 16917.1 apply.
This standard specifies the requirements and test methods of the type B RCD. Technical requirements and test methods specified in this standard type A is left
Supplementary device of the residual current technical requirements. B and B type RCCB RCBO at 1000Hz and below alternating sinusoidal residual current ripple
A three-phase DC residual current and residual smooth direct current power supply can provide protection.
This standard type B and type B RCCB RCBO can not be used in DC power systems.
Other technical requirements and test methods are not used or GB 16917.1 GB 16916.1 coated products where the residual current
Under consideration.
Or the manufacturer for verification of compliance statement type test according to the standard test procedure in Appendix A or Appendix B is.
All test procedures B and B type RCCB RCBO type test in Table A. 1 or Table B. 1 below.
Note 1. In the standard throughout, the term "RCD" refers RCCB and RCBO.
Note 2. The 1-pole and 2-pole technical requirements are under consideration.
2 Normative references
Terms of the following documents become provisions of this standard by reference in this standard. For dated reference documents, all later
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to agreements based on this standard
Whether the latest versions of these documents. For undated references, the latest version applies to this standard.
GB/T 13870.1 current effects on human beings and livestock Part 1. General portion (GB/T 13870.1-2008, IEC /T S60479-1.
2005, IDT)
GB/T 13870.2 effect of current passing through the second portion of the body. special cases (GB/T 13870.2-1997, idt IEC 60479-
2. 1987)
Residual current operated circuit breaker without overcurrent protection for household and similar GB 16916.1-2003 (the RCCB) Part 1
Points. General rules (IEC 61008-1.1996, MOD)
GB 16917.1-2003 with household and similar uses overcurrent protection residual current operated circuit breaker (the RCBO) Part 1
Points. General rules (IEC 61009-1.1996, MOD)
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
No DC current ripple.
NOTE. When...