Ir directamente a la información del producto
1 de 12

PayPal, credit cards. Download editable-PDF and invoice in 1 second!

DY/T 8-2023 English PDF (DYT8-2023)

DY/T 8-2023 English PDF (DYT8-2023)

Precio habitual $425.00 USD
Precio habitual Precio de oferta $425.00 USD
Oferta Agotado
Los gastos de envío se calculan en la pantalla de pago.
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click DY/T 8-2023
Historical versions: DY/T 8-2023
Preview True-PDF (Reload/Scroll if blank)

DY/T 8-2023: Technical requirements and measurement methods for digital cinema LED auditorium
DY/T 8-2023
DY
FILMDOM STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 37.060.99
CCS N40
Technical requirements and measurement methods for
digital cinema LED auditorium
ISSUED ON. NOVEMBER 20, 2023
IMPLEMENTED ON. NOVEMBER 20, 2023
Issued by. State Film Administration
Table of Contents
Foreword... 3
1 Scope... 4
2 Normative references... 4
3 Terms and definitions... 4
4 Abbreviations... 5
5 Composition of digital cinema LED auditorium... 5
6 Technical requirements... 6
7 Measurement method... 8
7.1 Measurement equipment... 8
7.2 Measurement signal... 10
7.3 Measurement environment and measurement conditions... 15
7.4 Measurement steps... 17
References... 28
Technical requirements and measurement methods for
digital cinema LED auditorium
1 Scope
This document specifies the optical and acoustic technical requirements and
corresponding measurement methods for digital cinema LED auditoriums.
This document applies to the operation and maintenance, testing and certification,
quality supervision, technical management and installation, commissioning, acceptance
of relevant equipments of digital cinema LED auditoriums.
2 Normative references
The contents of the following documents constitute essential clauses of this document
through normative references in the text. Among them, for dated references, only the
version corresponding to that date applies to this document; for undated references, the
latest version (including all amendments) applies to this document.
GY/T 311-2017 Technical requirements and methods of measurement of audio-
visual environment for cinema
GY/T 312-2017 Cinematography - B-chain electro-acoustic response of motion-
picture control rooms and indoor theatres - Specifications and measurements
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Digital cinema LED projection system
A system used to realize digital movie program decoding and playback and LED
digital projection, which is mainly composed of digital movie playback server, LED
controller, LED display screen, sound reproduction system.
3.2
Digital cinema LED auditorium
An auditorium that uses a digital cinema LED projection system for movie
projection.
3.3
Electro-optic transfer characteristic
The relationship between the input code value and the display brightness of the LED
display, which is expressed by a characteristic value.
3.4
Stereoscopic extinction ratio
The ratio -- of the left eye (right eye) image brightness to the crosstalk light and
ambient light, which is used to measure the left eye (right eye) image brightness's
immunity to crosstalk light and ambient light.
4 Abbreviations
The following abbreviations apply to this document.
HDR. High Dynamic Range
LED. Light-Emitting Diode
SDR. Standard Dynamic Range
5 Composition of digital cinema LED auditorium
The digital cinema LED auditorium consists of a digital cinema LED projection system
and other auxiliary systems. The digital cinema LED projection system mainly consists
of a digital cinema playback server, an LED controller, an LED display screen, a sound
reproduction system, as shown in Figure 1.
- Receiving angle. ≤ 1°;
- Accuracy. ≤ ±2%.
7.1.4 Spectroradiometer
The spectroradiometer shall meet the following requirements.
- Wavelength range. 380 nm ~ 780 nm;
- Measurement bandwidth. ≥ 2.5 nm ~ 20 nm;
- Receiving angle. ≤ 1°;
- Chromaticity accuracy x, y. ≤ ±0.002.
7.1.5 Reflectivity tester
The reflectivity tester shall meet the following requirements.
- It can measure specular reflectivity and diffuse reflectivity;
- Illumination. d/8 integrating sphere structure (diffuse illumination);
- Integrating sphere size. ≥ Ø54 mm;
- Light source. Pulse xenon lamp, quantity ≥ 2, can simulate standard illuminants A,
C, D50, D65, etc.;
- Wavelength range. ≥ 360 nm ~ 740 nm;
- Reflectivity measurement range. ≥ 0% ~ 175%;
- Display resolution. 0.01.
7.1.6 Noise signal generator
It shall meet the requirements of 5.2.4 of GY/T 311-2017.
7.1.7 Measurement microphone
It shall meet the requirements of 5.2.5 of GY/T 311-2017.
7.1.8 Sound level meter
It shall meet the requirements of 5.2.6 of GY/T 311-2017.
7.1.9 Filter
It shall meet the requirements of 5.2.7 of GY/T 311-2017.
7.2.2.2 HDR
Measurement signal with signal encoding value (X' = 2524, Y' = 2546, Z' = 2583).
7.2.3 Black field measurement signal
7.2.3.1 SDR
Measurement signal with signal encoding value (X' = 122, Y' = 128, Z' = 125).
7.2.3.2 HDR
Measurement signal with signal encoding value (X' = 60, Y' = 62, Z' = 65).
7.2.4 Red field measurement signal
7.2.4.1 SDR
Measurement signal with signal encoding values (X' = 2901, Y' = 2171, Z' = 100).
7.2.4.2 HDR
Measurement signal with signal encoding values (X' = 2234, Y' = 1925, Z' = 68).
7.2.5 Green field measurement signal
7.2.5.1 SDR
Measurement signal with signal encoding values (X' = 2417, Y' = 3493, Z' = 1222).
7.2.5.2 HDR
Measurement signal with signal encoding values (X' = 1988, Y' = 2387, Z' = 1327).
7.2.6 Blue field measurement signal
7.2.6.1 SDR
The measurement signal with signal encoding value (X' = 2014, Y' = 1416, Z' = 3816).
7.2.6.2 HDR
The measurement signal with signal encoding value (X' = 1871, Y' = 1525, Z' = 2565).
7.2.7 “Black to white” grayscale measurement signal
7.2.7.1 SDR
The measurement signal is divided into 10 groups of images. The signal encoding value
requirements are as shown in Table 3.
a) Ambient temperature. 15 °C ~ 35 °C;
b) Relative humidity. 10% ~ 90%;
c) Atmospheric pressure. 86 kPa ~ 106 kPa;
d) Voltage amplitude. 220 V ± 10 V AC;
e) Nominal frequency. 50 Hz.
7.3.2 Measurement conditions
The measurement conditions are as follows.
a) All measurements shall be carried out in the normal viewing environment of the
auditorium;
b) All equipment shall be in normal and stable working state, or configured
according to the measurement requirements;
c) All measurement signals shall be played and output to the LED display screen by
the digital movie playback server;
d) The measurement of the optical system should be carried out within the range of
qualified color reproduction at the center of the LED display screen;
e) When measuring the optical system, it shall be carried out after the light output of
the LED display screen is stable (thermal stabilization time is not less than 20
minutes) and the stereo projection equipment is stable (stereo projection
equipment is exposed to light for not less than 15 minutes);
f) When measuring the optical system, the optical measuring instrument is set up at
the center of the seating area of the auditorium, 1.15 m above the selected seat
floor; the measuring lens is aimed at the center of the LED display screen and has
a clear focus;
g) When measuring the stereo projection optical system, the stereo glasses are placed
horizontally in front of the lens of the optical measuring instrument; the lens shall
be perpendicular to the measurement axis and not block the instrument
measurement;
h) After each time the acoustic measurement equipment is turned on, the system shall
be calibrated before the corresponding acoustic measurement...
Ver todos los detalles