GB 12955-2008 English PDF (GB12955-2008)
GB 12955-2008 English PDF (GB12955-2008)
Prix habituel
$85.00 USD
Prix habituel
Prix promotionnel
$85.00 USD
Prix unitaire
/
par
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click GB 12955-2008
Historical versions: GB 12955-2008
Preview True-PDF (Reload/Scroll if blank)
GB 12955-2008: Fire resistant door sets
GB 12955-2008
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 13.220.50
C 82
Replacing GB 12955-1991, GB 14101-1993
Fire resistant doorsets
防火门
ISSUED ON: APRIL 22, 2008
IMPLEMENTED ON: JANUARY 01, 2009
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 4
1 Scope ... 7
2 Normative references ... 7
3 Terms and definitions ... 8
4 Classification, code and tag ... 10
5 Requirements ... 13
5.1 General requirements ... 13
5.2 Material ... 13
5.3 Fittings ... 15
5.4 Processing technique and appearance quality ... 17
5.5 Door leaf quality ... 17
5.6 Size limit deviation ... 18
5.7 Form-position tolerance ... 18
5.8 Fit tolerance ... 18
5.9 Flexibility ... 19
5.10 Reliability ... 19
5.11 Fire resistance ... 19
6 Test methods ... 19
6.1 Requirement for specimen ... 19
6.2 Accuracy of instrument and equipment ... 20
6.3 Material ... 20
6.4 Fittings ... 21
6.5 Processing technique and appearance quality ... 23
6.6 Door leaf quality ... 23
6.7 Dimensional tolerance ... 23
6.8 Tolerance of form and position ... 26
6.9 Fit tolerance ... 30
6.10 Flexibility ... 32
6.11 Reliability ... 32
6.12 Fire resistance ... 33
7 Inspection rules ... 33
7.1 Factory-exit inspection ... 33
7.2 Type inspection ... 34
8 Marking, packaging, transportation and storage ... 36
Annex A (normative) Requirements and test methods for flameproof locks ... 38
Annex B (normative) Fire resistance requirements and test methods for fire
resistant gemels (hinges) ... 39
Annex C (normative) Fire resistance requirements and test methods for fire
resistant sequence controllers ... 40
Annex D (normative) Fire resistance requirements and test methods for fire
resistant bolts ... 41
Foreword
Subclause 7.2 of Clause 5 of this Standard is compulsory; other clauses
of this Standard are voluntary.
This Standard replaces GB 12955-1991 “General technical conditions for steel
fire door” and GB 14101-1993 “Wood fire door - General technical conditions”.
Compared with GB 12955-1991 and GB 14101-1993, the major changes are
as follows:
- ADD the content of the classification of fire resistant doorsets according to
material (see 4.1);
- MODIFY the classification of fire resistance of fire resistant doorsets, from
the original A, B, C to fully insulated doorsets (type A), partially insulated
doorsets (type B) and no insulated doorsets (type C) (4.3 in GB 12955-
1991, 4.1 in GB 14101-1993 and 4.4 of this Standard);
- Requirement for the material of fire resistant doorsets is more specific: apart
from non-metallic material, ADD the requirements for combustion
performance and burning flue-gas toxicant (5.1 in GB 12955-1991 and GB
14101-1993 and 5.2 in this Standard);
- DELETE the requirements of wind pressure deformability resistance, air
penetration resistance and rainfall penetration resistance for fire resistant
timber doorsets used as the building exterior door;
- Performance requirements for fireproof locks are more specific (5.1.3 in GB
12955-1991, 5.1.4 in GB 14101-1993 and 5.3.1 of this Standard);
- Performance requirements for fireproof hinges (gemels) are more specific
(5.1.3 and 5.1.4 in GB 12955-1991, 5.1.4 in GB 14101-1993 and 5.3.2 of
this Standard);
- Performance requirements for door-closing devices are more specific (5.1.3
in GB 12955-1991, 5.1.4 in GB 14101-1993 and 5.3.3 of this Standard);
- Performance requirements for fire resistant glass are more specific (5.1.3
in GB 12955-1991, 5.1.3 in GB 14101-1993 and 5.3.7 of this Standard);
- ADD the quality requirements and test methods for the door leaf of fire
resistant doorsets (see 5.5 and 6.6);
- ADD the requirements and test methods for the degree of curvature in the
width direction of the door leaf (see 5.7 and 6.8.3);
Fire resistant doorsets
1 Scope
This Standard specifies the classification, code and tag, requirements, test
methods, inspection rules, marking, packaging, transportation and storage of
fire resistant doorsets.
This Standard is applicable to fire resistant timber, steel and timber-steel side
hung doorsets and other material fire resistant. As for fire resistant doorsets of
other open modes, it may refer to this Standard.
2 Normative references
The following documents contain the provisions which, through reference in this
Standard, become the provisions of this Standard. For dated references, their
subsequent amendments (excluding corrigendum) or revisions do not apply to
this Standard. However, the parties who enter into agreement based on this
Standard are encouraged to investigate whether the latest versions of these
documents are applicable. For undated reference documents, the latest
versions apply to this Standard.
GB/T 708 Dimension shape weight and tolerance for cold-rolled steel plates
and sheets
GB/T 709 Dimensions, shape, weight and tolerances for hot-rolled plates
and sheets
GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1:
Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot
inspection
GB/T 4823-1995 Defects in sawn timber (eqv ISO 1029:1974)
GB/T 5823-1986 Doors and windows for building - Terminology
GB/T 5824 Size system of opening for windows and doors in building
GB/T 5907-1986 Fundamental terminology of fire protection; Part 1
GB/T 6388 Transport package shipping mark
GB/T 7633 Fire resistance tests - Door and shutter assemblies
3.3
fire resistant steel doorsets
Doorsets with certain fire resistance, of which the door frame, door leaf frame
and door leaf panel are made of steel material. If the door leaf is filled with
materials, it will be filled with fireproof and heat-insulating materials that are
non-toxic and harmless to the human body. It is equipped with fire-resistant
hardware components.
3.4
fire resistant timber doorsets with steel structure
Doorsets with certain fire resistance, of which the door frame, door leaf frame
and door leaf panel are made of steel and flame-retardant wood or flame-
retardant wood products. If the door leaf is filled with materials, it will be filled
with fireproof and heat-insulating materials that are non-toxic and harmless to
the human body. It is equipped with fire-resistant hardware components.
3.5
other material fire resistant doorsets
Doorsets with certain fire resistance, of which the door frame, door leaf frame
and door leaf panel are made of inorganic non-combustible materials other than
steel, flame-retardant wood or flame-retardant wood products or partially made
of steel, flame-retardant wood, and flame-retardant wood products. If the door
leaf is filled with materials, it will be filled with fireproof and heat-insulating
materials that are non-toxic and harmless to the human body. It is equipped
with fire-resistant hardware components.
3.6
fully insulated doorsets
Within a specified period of time, doorsets that meet the requirements for fire
integrity and fire insulation.
3.7
partially insulated doorsets
Doorsets that meet the requirements for fire integrity and fire insulation within
a specified period of time greater than or equal to 0.50 h, and meet the
requirements for fire integrity when 0.50 h is exceeded.
Get QUOTATION in 1-minute: Click GB 12955-2008
Historical versions: GB 12955-2008
Preview True-PDF (Reload/Scroll if blank)
GB 12955-2008: Fire resistant door sets
GB 12955-2008
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 13.220.50
C 82
Replacing GB 12955-1991, GB 14101-1993
Fire resistant doorsets
防火门
ISSUED ON: APRIL 22, 2008
IMPLEMENTED ON: JANUARY 01, 2009
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 4
1 Scope ... 7
2 Normative references ... 7
3 Terms and definitions ... 8
4 Classification, code and tag ... 10
5 Requirements ... 13
5.1 General requirements ... 13
5.2 Material ... 13
5.3 Fittings ... 15
5.4 Processing technique and appearance quality ... 17
5.5 Door leaf quality ... 17
5.6 Size limit deviation ... 18
5.7 Form-position tolerance ... 18
5.8 Fit tolerance ... 18
5.9 Flexibility ... 19
5.10 Reliability ... 19
5.11 Fire resistance ... 19
6 Test methods ... 19
6.1 Requirement for specimen ... 19
6.2 Accuracy of instrument and equipment ... 20
6.3 Material ... 20
6.4 Fittings ... 21
6.5 Processing technique and appearance quality ... 23
6.6 Door leaf quality ... 23
6.7 Dimensional tolerance ... 23
6.8 Tolerance of form and position ... 26
6.9 Fit tolerance ... 30
6.10 Flexibility ... 32
6.11 Reliability ... 32
6.12 Fire resistance ... 33
7 Inspection rules ... 33
7.1 Factory-exit inspection ... 33
7.2 Type inspection ... 34
8 Marking, packaging, transportation and storage ... 36
Annex A (normative) Requirements and test methods for flameproof locks ... 38
Annex B (normative) Fire resistance requirements and test methods for fire
resistant gemels (hinges) ... 39
Annex C (normative) Fire resistance requirements and test methods for fire
resistant sequence controllers ... 40
Annex D (normative) Fire resistance requirements and test methods for fire
resistant bolts ... 41
Foreword
Subclause 7.2 of Clause 5 of this Standard is compulsory; other clauses
of this Standard are voluntary.
This Standard replaces GB 12955-1991 “General technical conditions for steel
fire door” and GB 14101-1993 “Wood fire door - General technical conditions”.
Compared with GB 12955-1991 and GB 14101-1993, the major changes are
as follows:
- ADD the content of the classification of fire resistant doorsets according to
material (see 4.1);
- MODIFY the classification of fire resistance of fire resistant doorsets, from
the original A, B, C to fully insulated doorsets (type A), partially insulated
doorsets (type B) and no insulated doorsets (type C) (4.3 in GB 12955-
1991, 4.1 in GB 14101-1993 and 4.4 of this Standard);
- Requirement for the material of fire resistant doorsets is more specific: apart
from non-metallic material, ADD the requirements for combustion
performance and burning flue-gas toxicant (5.1 in GB 12955-1991 and GB
14101-1993 and 5.2 in this Standard);
- DELETE the requirements of wind pressure deformability resistance, air
penetration resistance and rainfall penetration resistance for fire resistant
timber doorsets used as the building exterior door;
- Performance requirements for fireproof locks are more specific (5.1.3 in GB
12955-1991, 5.1.4 in GB 14101-1993 and 5.3.1 of this Standard);
- Performance requirements for fireproof hinges (gemels) are more specific
(5.1.3 and 5.1.4 in GB 12955-1991, 5.1.4 in GB 14101-1993 and 5.3.2 of
this Standard);
- Performance requirements for door-closing devices are more specific (5.1.3
in GB 12955-1991, 5.1.4 in GB 14101-1993 and 5.3.3 of this Standard);
- Performance requirements for fire resistant glass are more specific (5.1.3
in GB 12955-1991, 5.1.3 in GB 14101-1993 and 5.3.7 of this Standard);
- ADD the quality requirements and test methods for the door leaf of fire
resistant doorsets (see 5.5 and 6.6);
- ADD the requirements and test methods for the degree of curvature in the
width direction of the door leaf (see 5.7 and 6.8.3);
Fire resistant doorsets
1 Scope
This Standard specifies the classification, code and tag, requirements, test
methods, inspection rules, marking, packaging, transportation and storage of
fire resistant doorsets.
This Standard is applicable to fire resistant timber, steel and timber-steel side
hung doorsets and other material fire resistant. As for fire resistant doorsets of
other open modes, it may refer to this Standard.
2 Normative references
The following documents contain the provisions which, through reference in this
Standard, become the provisions of this Standard. For dated references, their
subsequent amendments (excluding corrigendum) or revisions do not apply to
this Standard. However, the parties who enter into agreement based on this
Standard are encouraged to investigate whether the latest versions of these
documents are applicable. For undated reference documents, the latest
versions apply to this Standard.
GB/T 708 Dimension shape weight and tolerance for cold-rolled steel plates
and sheets
GB/T 709 Dimensions, shape, weight and tolerances for hot-rolled plates
and sheets
GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1:
Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot
inspection
GB/T 4823-1995 Defects in sawn timber (eqv ISO 1029:1974)
GB/T 5823-1986 Doors and windows for building - Terminology
GB/T 5824 Size system of opening for windows and doors in building
GB/T 5907-1986 Fundamental terminology of fire protection; Part 1
GB/T 6388 Transport package shipping mark
GB/T 7633 Fire resistance tests - Door and shutter assemblies
3.3
fire resistant steel doorsets
Doorsets with certain fire resistance, of which the door frame, door leaf frame
and door leaf panel are made of steel material. If the door leaf is filled with
materials, it will be filled with fireproof and heat-insulating materials that are
non-toxic and harmless to the human body. It is equipped with fire-resistant
hardware components.
3.4
fire resistant timber doorsets with steel structure
Doorsets with certain fire resistance, of which the door frame, door leaf frame
and door leaf panel are made of steel and flame-retardant wood or flame-
retardant wood products. If the door leaf is filled with materials, it will be filled
with fireproof and heat-insulating materials that are non-toxic and harmless to
the human body. It is equipped with fire-resistant hardware components.
3.5
other material fire resistant doorsets
Doorsets with certain fire resistance, of which the door frame, door leaf frame
and door leaf panel are made of inorganic non-combustible materials other than
steel, flame-retardant wood or flame-retardant wood products or partially made
of steel, flame-retardant wood, and flame-retardant wood products. If the door
leaf is filled with materials, it will be filled with fireproof and heat-insulating
materials that are non-toxic and harmless to the human body. It is equipped
with fire-resistant hardware components.
3.6
fully insulated doorsets
Within a specified period of time, doorsets that meet the requirements for fire
integrity and fire insulation.
3.7
partially insulated doorsets
Doorsets that meet the requirements for fire integrity and fire insulation within
a specified period of time greater than or equal to 0.50 h, and meet the
requirements for fire integrity when 0.50 h is exceeded.