GB 18278.1-2015: Sterilization of health care products -- Moist heat -- Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
GB 18278.1-2015
Sterilization of health care products - Moist heat - Part 1. Requirements for the development, validation and routine control of a sterilization process for medical devices
ICS 11.080.01
C47
National Standards of People's Republic of China
Replacing GB 18278-2000, GB/T 20367-2006
Sterilization of health care products heat
Part 1. Medical device sterilization process development,
Validation and routine control
Part 1. Requirementsforthedevelopment, validationandroutinecontrol
(ISO 17665-1.2006, IDT)
Issued on. 2017-01-01 2015-12-10 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 Quality Management System Elements 8
5 sterilization factor characterization 9
6 features described processes and equipment 9
7 Products OK 12
8 process determines 12
9 Confirm 13
10 Routine monitoring and control 15
11 sterilized product release 16
12 to maintain the effectiveness of the process 16
Appendix A (informative) Guide 18
Annex B (informative) based on the state of the natural microflora inactivation process determines (based on bioburden method) 22
Annex C (informative) knowledge-based process of inactivation of the reference microorganisms and biological products to be sterilized load is determined (based on
Bioburden combined biological indicator method) 23
Annex D (normative) based on the reference microorganism inactivation traditional process determines (overkill approach) 24
Annex E (informative) run cycle 26
References 30
Foreword
All technical content in this Part of GB 18278 is mandatory.
GB 18278 "Sterilization of health care products heat" is divided into the following two parts.
--- Part 1. Development of medical equipment sterilization process, validation and routine control requirements;
--- Part 2. Application guide.
This is part of the GB Part 118 278.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section and GB/T 18278.2 together instead of GB 18278-2000 "Sterilization of health care products for validation and routine control requirements
Confirmed that health care products Sterilization of health care institutions moist heat sterilization industrial heat sterilization "and GB/T 20367-2006" and conventional control
Claim". Compared with GB 18278-2000 and GB/T 20367-2006 main differences are as follows.
--- For industrial moist heat sterilization and heat sterilization two aspects of health care organizations;
--- Increasing the sterilization factor features, product definition, process definition, installation qualification, operational qualification, to maintain the effectiveness of the sterilization process technology
content.
This part identical with ISO 17665-1.2006 "developed heat sterilization of health care products for medical device sterilization process, indeed
Recognize and routine control. "
Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB 18281.1-2015 Sterilization of health care products - Biological indicators - Part 1. General (ISO 11138-1.2006,
IDT);
--- GB 18281.3-2015 Sterilization of health care products - Biological indicators - Part 3. Biological indicators for moist heat sterilization
(ISO 11138-3.2006, IDT);
--- GB 18282.1-2015 Sterilization of health care products - Chemical indicators - Part 1. General (ISO 11140-1.2005,
IDT);
--- GB 18282.3-2009 Sterilization of health care products - Chemical indicators - Part 3. Class BD for steam penetration test
The Class 2 indicator systems (ISO 11140-3.2007, IDT);
--- GB 18282.4-2009 Sterilization of health care products - Chemical indicators - Part 4. BD used to replace steam penetration test
Examination II indicators (ISO 11140-4.2007, IDT);
--- GB 18282.5-2015 Sterilization of health care products chemical indicators - Part 5. Class of air exclusion measure for BD
Examination II indicators (ISO 11140-5.2007, IDT);
--- GB/T 19022-2003 Measurement management systems for measurement processes and measuring equipment (ISO 10012-2003, IDT);
--- GB/T 19633.1-2015 terminally sterilized medical device packaging - Part 1. materials, sterile barrier systems and packaging systems
Requirements (ISO 11607-1.2006, IDT);
--- GB/T 19633.2-2015 terminally sterilized medical device packaging - Part 2. Confirm forming, sealing and assembly processes to
Demand (ISO 11607-2.2006, IDT);
Part 1 sterilization Microbiological Methods --- GB/T 19973.1-2015 medical devices. the total number of microorganisms on the product test
Set (ISO 11737-1.2006, IDT);
--- GB /sterilization Methodology Part 2 microbial T 19973.2-2005 Medical Devices. Confirm sterile test sterilization procedures
Test (ISO 11737-2.1998, IDT);
--- YY/T 0287-2003 medical device quality management system for regulatory requirements (ISO 13485.2003, IDT);
--- Processing YY/T 0802-2010 sterilization of medical equipment manufacturers to provide the information may be repeated sterilization of medical devices
(ISO 17664.2004, IDT).
This part made the following editorial changes.
--- According to GB/T 1.1 requirements of a number of editorial changes;
--- Deleted international standards foreword;
--- Introduction of international standards and references appear to replace the corresponding country standards.
Please note that some of the content of this document may involve patents. Issuer of this document does not assume responsibility for the identification of these patents.
This part is proposed by the China Food and Drug Administration.
This part of the National Standardization Technical Committee disinfection technology and equipment (SAC/TC200) centralized.
This section drafted by. Shandong Xinhua Medical Instrument Co., Ltd., Michael Di Jincheng Medical Devices Co., Ltd., the State Food and Drug
Goods Administration of Guangzhou Medical Device Quality Supervision and Inspection Center, Belimed Medical Equipment (Shanghai) Co., Ltd.
The main drafters of this section. Wang Hongmin, Lv Liansheng, Xu Honglei, .Image, Xuwei Xiong, Huang Xiulian.
This part of the standard replaces the previous editions are.
--- GB 18278-2000;
--- GB/T 20367-2006.
introduction
Sterile medical devices is a non-living micro-organisms products. International Standard specifies confirm the sterilization process and routine control of when
Medical devices must be provided in sterile form, it should be sterilized before its various unintended microbiological contamination to a minimum. Even medical devices
Mechanical products to meet the quality management system (for example. ISO 13485) requirements under standard production conditions produced before sterilization still with
A small amount of micro-organisms, such products shall be guilty of non-sterile products. Purpose of sterilization is to inactivate microorganisms, non-sterile products into sterile
product.
Physical factors and/sterilization of medical devices using kinetic or chemical factors on pure cultures of microorganisms surviving microorganisms can be inactivated general
The number was exponential relationship between the degree of sterilization and be a good description. This means that regardless of the degree of sterilization, there must exist a microorganism
Live probability. For the treatment has been given, the remaining microorganism survival probability depends on the number of m...