AQ 4273-2016: Safety specifications for dedusting system used in dust explosion hazardous area
AQ 4273-2016
GB
WORK SAFETY INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 13.100
C 65
RECORD NO.. 56078-2016
Safety Specifications for Dedusting System
Used in Dust Explosion Hazardous Area
ISSUED ON. AUGUST 29, 2016
IMPLEMENTED ON. MARCH 1, 2017
Issued by. State Administration of Work Safety of the People’s Republic
of China
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Terms and Definitions ... 5
4 General ... 6
5 Deduster ... 8
6 Dust Hoods and Dust Cabinets ... 12
7 Air-Duct ... 12
8 Fans ... 14
9 Explosion-proof Device ... 14
10 Electrical Safety and Anti-Static Measures ... 16
11 Deduster and Air-duct’s Layout and Safety Measures ... 16
12 Dust Cleaning ... 18
13 Maintenance-Overhaul, Testing and Verification ... 19
Foreword
All the technical content of this Standard is compulsory, except Clauses 1, 2 and
3, 5.1.4c), 5.1.7c), 6.3.7.1.1, 7.1.6, 7.1.7, 9.3a).
This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This Standard was proposed by the Fourth Supervision Division of the State
Administration of Work Safety.
This Standard shall be under the jurisdiction of Technical Subcommittee 5 on Dust
Explosion Prevention of National Technical Committee 288 on Work Safety of
Standardization Administration of China (SAC/TC 288/SC 5).
The drafting organizations of this Standard. Guangdong Jinfangyuan Safety
Technology Testing Co., Ltd., Sinosteel Corporation Wuhan Safety and Environmental
Protection Research Institute. Safety Enginerring Research Center of NEU,
Guangzhou Gan Feng Machinery Equipment Co., Ltd., Guangzhou Tongsheng
Environmental Protection Technology Co., Ltd.
The main drafters of this Standard. Meng Xianwei, Xu Guoping, Li Gang, Zhao Danli,
Meng Tingting, Zhou Jinbiao, Zhang Wei, Feng Gang, Feng Guishen, Luo Xingyue,
Xiao Gongzeng.
Safety Specifications for Dedusting System
Used in Dust Explosion Hazardous Area
1 Scope
This Standard specifies the requirements for explosion-proof measures, maintenance
and overhaul, detection and verification of dedusting system that are used in dust
explosion hazardous area.
This Standard applies to the design, manufacturing, installation, acceptance, use and
maintenance of dedusting system that are used in dust explosion hazardous area.
This Standard does not apply to dedusting system that are used in production sites of
chemicals, mining, tunneling, fireworks and firecrackers, and commercial explosive
materials.
2 Normative References
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition dated applies to this document. For
undated references, the latest edition of the referenced documents (including all
amendments) applies to This Standard.
GB 2894, Safety Signs and Guideline for the Use
GB 7231, Basic Identification Colors and Code Indications and Safety Sign for
Industrial Pipelines
GB 12158, General Guideline for Preventing Electrostatic Accidents
GB 12476.1, Electrical Apparatus for Use in the Presence of Combustible Dust -
Part 1. General Requirements
GB 12476.2, Electrical Apparatus for Use in the Presence of Combustible Dust -
Part 2. Selection and Installation
GB 15577, Safety Regulations for Dust Explosion Prevention and Protection
GB/T 15605, Guide for Pressure Venting of Dust Explosions
GB/T 16758, The Classification and Technical Specification of Exhaust Hood
GB/T 17919, Directives for Dust Explosion Protection for Deduster in Dust
Explosion Hazardous Area
GB 50019, Code for Design of Heating Ventilation and Air Conditioning in Industrial
Buildings
GB 50057, Design Code for Protection of Structures against Lightning
GB 50058, Code for Design of Electrical Installations in Explosive Atmospheres
AQ 7005, Safety Requirements for the Use of Woodworking Machinery
3 Terms and Definitions
For the purposes of this Standard, the following terms and definitions apply.
3.1
dust
small solid particles in the atmosphere which settle out under their own weight, but
which may remain suspended in air for some time.
3.2
combustible dust
dust that can burn or glow in air and could form explosive mixtures with air at
atmospheric pressure and normal temperatures.
3.3
dust explosion hazardous area
the sites at where combustible dust, combustion-supporting gas or ignition source is
present.
3.4
dedusting system
a system which is used to gather the solid particles in gas- and solid-phase flows,
comprising dust collection hood or dust collection cabinet, air hose, fan, dust catcher
and control device.
3.5
explosion-proof device
the device which adopt the technique of prevention and control of dust explosion, to
prevent the formation of dust clouds or possible ignition sources and put combustible
If there exists toxic, corrosive dust and combustible dust, the deduster and air-duct
shall not adopt explosion-venting device for pressure release; it shall select the
explosion-suppression device that can charge fire extinguishing gas or powder media
into the deduster and air-duct to extinguish flames.
4.3 The box of the deduster shall meet the following requirements.
a) The box is made of a steel metallic material, or select flame-resistant materials
and take anti-static measures if other materials are used; it shall not use
aluminium metallic materials.
b) The design strength of the box shall be able to withstand the maximum explosive
pressure generated after explosion-proof measures are adopted; and the box
installed in buildings shall adopt steel metallic materials and welding structures.
c) The included angles between the box-plates of a square-box shall be arc-treated.
d) The internal surface of the box shall be smooth; the box made of steel metallic
material shall be treated for rust-proofing; aluminium coating shall not be used.
4.4 The operating conditions of the dry deduster shall include continuous dust
discharging and continuous dust conveying. It should not adopt settling chamber to
perform dust treatment.
4.5 The deduster used in explosion hazardous areas of aluminium-magnesium dust
and wooden product dust shall work under negative pressure conditions; for other dust
explosion areas, if dedusting system adopts positive pressure to blow dust, then it shall
adopt reliable measures to prevent the ignition sources.
4.6 Aluminium-magnesium dust shall not share the same dedusting system with iron
dust and other kinds of combustible dust; and the dedusting system shall not connect
with air-duct and equipment that carry combustible gas, high-temperature gas, smoke
dust and other industrial gases.
4.7 The entry of sparks into the air-duct and deduster of the dedusting system is not
allowed. For the production-processing system that exists suction of sparks into the
air-duct through dust hood or dust cabinet, it shall adopt the measures to block sparks
to enter into the air-duct and deduster.
4.8 The dedusting system shall be set up with control device meeting the following
requirements.
a) Start and stop. The dedusting system shall be started before the production-
processing system. When the production-processing system is stopped, the
dedusting system shall be delayed for 10 min before being stopped.
b) Protection interlock. The dedusting system shall be set up with protection
interlocking ...
Get QUOTATION in 1-minute: Click AQ 4273-2016
Historical versions: AQ 4273-2016
Preview True-PDF (Reload/Scroll if blank)
AQ 4273-2016: Safety specifications for dedusting system used in dust explosion hazardous area
AQ 4273-2016
GB
WORK SAFETY INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 13.100
C 65
RECORD NO.. 56078-2016
Safety Specifications for Dedusting System
Used in Dust Explosion Hazardous Area
ISSUED ON. AUGUST 29, 2016
IMPLEMENTED ON. MARCH 1, 2017
Issued by. State Administration of Work Safety of the People’s Republic
of China
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Terms and Definitions ... 5
4 General ... 6
5 Deduster ... 8
6 Dust Hoods and Dust Cabinets ... 12
7 Air-Duct ... 12
8 Fans ... 14
9 Explosion-proof Device ... 14
10 Electrical Safety and Anti-Static Measures ... 16
11 Deduster and Air-duct’s Layout and Safety Measures ... 16
12 Dust Cleaning ... 18
13 Maintenance-Overhaul, Testing and Verification ... 19
Foreword
All the technical content of this Standard is compulsory, except Clauses 1, 2 and
3, 5.1.4c), 5.1.7c), 6.3.7.1.1, 7.1.6, 7.1.7, 9.3a).
This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This Standard was proposed by the Fourth Supervision Division of the State
Administration of Work Safety.
This Standard shall be under the jurisdiction of Technical Subcommittee 5 on Dust
Explosion Prevention of National Technical Committee 288 on Work Safety of
Standardization Administration of China (SAC/TC 288/SC 5).
The drafting organizations of this Standard. Guangdong Jinfangyuan Safety
Technology Testing Co., Ltd., Sinosteel Corporation Wuhan Safety and Environmental
Protection Research Institute. Safety Enginerring Research Center of NEU,
Guangzhou Gan Feng Machinery Equipment Co., Ltd., Guangzhou Tongsheng
Environmental Protection Technology Co., Ltd.
The main drafters of this Standard. Meng Xianwei, Xu Guoping, Li Gang, Zhao Danli,
Meng Tingting, Zhou Jinbiao, Zhang Wei, Feng Gang, Feng Guishen, Luo Xingyue,
Xiao Gongzeng.
Safety Specifications for Dedusting System
Used in Dust Explosion Hazardous Area
1 Scope
This Standard specifies the requirements for explosion-proof measures, maintenance
and overhaul, detection and verification of dedusting system that are used in dust
explosion hazardous area.
This Standard applies to the design, manufacturing, installation, acceptance, use and
maintenance of dedusting system that are used in dust explosion hazardous area.
This Standard does not apply to dedusting system that are used in production sites of
chemicals, mining, tunneling, fireworks and firecrackers, and commercial explosive
materials.
2 Normative References
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition dated applies to this document. For
undated references, the latest edition of the referenced documents (including all
amendments) applies to This Standard.
GB 2894, Safety Signs and Guideline for the Use
GB 7231, Basic Identification Colors and Code Indications and Safety Sign for
Industrial Pipelines
GB 12158, General Guideline for Preventing Electrostatic Accidents
GB 12476.1, Electrical Apparatus for Use in the Presence of Combustible Dust -
Part 1. General Requirements
GB 12476.2, Electrical Apparatus for Use in the Presence of Combustible Dust -
Part 2. Selection and Installation
GB 15577, Safety Regulations for Dust Explosion Prevention and Protection
GB/T 15605, Guide for Pressure Venting of Dust Explosions
GB/T 16758, The Classification and Technical Specification of Exhaust Hood
GB/T 17919, Directives for Dust Explosion Protection for Deduster in Dust
Explosion Hazardous Area
GB 50019, Code for Design of Heating Ventilation and Air Conditioning in Industrial
Buildings
GB 50057, Design Code for Protection of Structures against Lightning
GB 50058, Code for Design of Electrical Installations in Explosive Atmospheres
AQ 7005, Safety Requirements for the Use of Woodworking Machinery
3 Terms and Definitions
For the purposes of this Standard, the following terms and definitions apply.
3.1
dust
small solid particles in the atmosphere which settle out under their own weight, but
which may remain suspended in air for some time.
3.2
combustible dust
dust that can burn or glow in air and could form explosive mixtures with air at
atmospheric pressure and normal temperatures.
3.3
dust explosion hazardous area
the sites at where combustible dust, combustion-supporting gas or ignition source is
present.
3.4
dedusting system
a system which is used to gather the solid particles in gas- and solid-phase flows,
comprising dust collection hood or dust collection cabinet, air hose, fan, dust catcher
and control device.
3.5
explosion-proof device
the device which adopt the technique of prevention and control of dust explosion, to
prevent the formation of dust clouds or possible ignition sources and put combustible
If there exists toxic, corrosive dust and combustible dust, the deduster and air-duct
shall not adopt explosion-venting device for pressure release; it shall select the
explosion-suppression device that can charge fire extinguishing gas or powder media
into the deduster and air-duct to extinguish flames.
4.3 The box of the deduster shall meet the following requirements.
a) The box is made of a steel metallic material, or select flame-resistant materials
and take anti-static measures if other materials are used; it shall not use
aluminium metallic materials.
b) The design strength of the box shall be able to withstand the maximum explosive
pressure generated after explosion-proof measures are adopted; and the box
installed in buildings shall adopt steel metallic materials and welding structures.
c) The included angles between the box-plates of a square-box shall be arc-treated.
d) The internal surface of the box shall be smooth; the box made of steel metallic
material shall be treated for rust-proofing; aluminium coating shall not be used.
4.4 The operating conditions of the dry deduster shall include continuous dust
discharging and continuous dust conveying. It should not adopt settling chamber to
perform dust treatment.
4.5 The deduster used in explosion hazardous areas of aluminium-magnesium dust
and wooden product dust shall work under negative pressure conditions; for other dust
explosion areas, if dedusting system adopts positive pressure to blow dust, then it shall
adopt reliable measures to prevent the ignition sources.
4.6 Aluminium-magnesium dust shall not share the same dedusting system with iron
dust and other kinds of combustible dust; and the dedusting system shall not connect
with air-duct and equipment that carry combustible gas, high-temperature gas, smoke
dust and other industrial gases.
4.7 The entry of sparks into the air-duct and deduster of the dedusting system is not
allowed. For the production-processing system that exists suction of sparks into the
air-duct through dust hood or dust cabinet, it shall adopt the measures to block sparks
to enter into the air-duct and deduster.
4.8 The dedusting system shall be set up with control device meeting the following
requirements.
a) Start and stop. The dedusting system shall be started before the production-
processing system. When the production-processing system is stopped, the
dedusting system shall be delayed for 10 min before being stopped.
b) Protection interlock. The dedusting system shall be set up with protection