QC/T 911-2023: Power supply vehicle
QC/T 911-2023
QC
AUTOMOTIVE INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 43.160
CCS T 59
Replacing QC/T 911-2013
Power Supply Vehicle
ISSUED ON: APRIL 21, 2023
IMPLEMENTED ON: NOVEMBER 1, 2023
Issued by: Ministry of Industry and Information Technology of the People’s
Republic of China
Table of Contents
Foreword ... 6
1 Scope ... 10
2 Normative References ... 10
3 Terms and Definitions ... 12
4 Technical Requirements ... 13
5 Test Methods ... 23
6 Inspection Rules ... 25
7 Marking and Instruction Manual ... 27
8 Attached Document, Transportation and Storage ... 27
Power Supply Vehicle
1 Scope
This Document specifies the technical requirements, test methods, inspection rules, marking,
packaging, transportation and storage of power supply vehicles.
This Document is applicable to power supply vehicles using a stereotyped car chassis or whole-
vehicle modification, equipped with a power frequency three-phase AC diesel generator set of
8kW to 1250 kW and a rated voltage of 400V. Power supply semi-trailers shall be implemented
by reference.
2 Normative References
The provisions in following documents become the essential provisions of this Document
through reference in this Document. For the dated documents, only the versions with the dates
indicated are applicable to this Document; for the undated documents, only the latest version
(including all the amendments) is applicable to this Document.
GB 1495 Permissible noise limit emitted by power-driven vehicles
GB 1589 Limits of dimensions, axle load and masses for road vehicles
GB/T 2819-1995 General Specification for Mobile Electric Power Plant
GB/T 2820.1-2022 Reciprocating internal combustion engine driven alternating current
generating sets - Part 1: Application, ratings and performance
GB/T 2900.41 Electrotechnical terminology - Primary and secondary cells and batteries
GB/T 6072.1 Reciprocating internal combustion engines - Performance - Part 1:
Declarations of power fuel and lubricating oil consumptions and test methods - Additional
requirements for engines for general use
GB 7258 Safe specification for motor vehicles operating on roads
GB/T 7260.1 Uninterruptible power systems (UPS) – Part 1-1: General and Safety
Requirements for UPS used in operator access areas
GB/T 7260.2 Uninterruptible power systems (UPS)―Part 2: Electromagnetic
compatibility (EMC) requirements
3 Terms and Definitions
For the purposes of this Document, the terms and definitions given in JB/T 8194 and GB/T
2900.41 and the following apply.
3.1 Power supply vehicle
The special vehicle that is equipped with a generator set, optional uninterruptible power supply
system, transmission lines and other devices, and is used to provide power.
3.2 Compartment
The compartment body that is used to protect the generator set and related accessories in the
power supply vehicle.
3.3 Ventilation system
The ventilation device that provides combustion and cooling air to the generator set (including
engine and generator) in the compartment.
3.4 Rated output
The rated power mentioned in this Document is the basic power of the generator set specified
in 14.3.3 of GB/T 2820.1-2022.
3.5 Uninterruptible power system
A power system that is composed of a combination of converters, switches and energy storage
systems to maintain load power continuity when the input power fails.
NOTE: Energy storage systems can be divided into mechanical energy storage systems and rechargeable
energy storage systems (such as batteries).
3.6 Rechargeable energy storage system
An energy storage system that is rechargeable and provides electrical energy.
EXAMPLE: Such as lithium-ion batteries, capacitors, etc.
3.7 Battery management system
A system that monitors battery status (temperature, voltage, current, state of charge, etc.) and
provides communication interfaces and protection for the battery.
3.8 Delay time
The uninterruptible power supply operates at rated capacity and the time it takes for the voltage
of the rechargeable energy storage system to drop to the discharge cut-off voltage.
4 Technical Requirements
4.1 General
4.1.1 The power supply vehicle shall comply with the requirements of this Document and be
manufactured in accordance with the product drawings and technical documents approved by
the manufacturer's prescribed procedures.
4.1.2 Purchased and outsourced parts shall comply with the provisions of relevant standards
and have certificates of conformity from the manufacturer. They can only be used after passing
the inspection. All self-made parts can be assembled only after passing the inspection.
4.2 Environmental conditions
4.2.1 Environmental conditions for the rated power output of the power supply vehicle: Altitude
is 0m; ambient temperature is 25°C; and relative humidity is 30%.
4.2.2 The power supply vehicle shall be able to output the corrected specified power and work
reliably under the following conditions. The conditions shall be specified in the product
technical documents:
---The altitude does not exceed 4000m.
--- The low-temperature lower limits of the ambient temperature are: -40°C, -25°C, -10°C,
5°C; the high-temperature upper limits are: 40°C, 45°C, 50°C; the lower limit value and
upper limit value of the ambient temperature are each one of the above data.
--- Maximum relative humidity does not exceed 90% (25°C).
---The rainfall shall not exceed 8mm/h.
4.2.3 When the power supply vehicle is running, the working site shall be able to ensure that
the longitudinal (front and rear) horizontal inclination of the power supply vehicle is no more
than 6°; and the transverse (left and right) horizontal inclination is no more than 5°.
4.2.4 When the actual environmental conditions are worse than those specified in 4.2.1, for
non-supercharged and mechanically supercharged diesel engine units; the power is converted
into electrical power after converting the diesel engine power under test conditions according
to the provisions of GB/T 6072.1; but the maximum electrical power shall not exceed the rated
power of the generator. For units using other prime movers, the power correction method shall
be in accordance with the provisions of the product technical documents.
4.3 Whole vehicle
two-pole socket wiring shall meet the wiring specifications of zero on the left and fire on the
right.
4.3.13 Power supply vehicles with a rated power greater than 20kW shall be equipped with a
generator set starting battery voltage detection device. When the generator set starting battery
voltage is too low, there shall be an alarm indication.
4.3.14 A power supply vehicle with a rated power greater than 20kW shall be equipped with an
AC 220V or AC 380V charging device. After being connected, the starting battery can be
charged to the generator set.
4.3.15 Power supply vehicles with a rated power greater than 20kW should be equipped with a
camera with night vision function inside the compartment to monitor internal conditions from
outside the compartment.
4.3.16 For power supply vehicles with a length of the whole vehicle greater than 6m, the cab
shall be equipped with a reversing monitoring system.
4.3.17 The starting capability of the power supply vehicle shall meet the following requirements:
--- Normal temperature start: When the ambient temperature of the power vehicle generator
set is greater than 10°C, the unit shall be able to start successfully within ...