1
/
の
10
PayPal, credit cards. Download editable-PDF and invoice in 1 second!
MT 209-1990 English PDF
MT 209-1990 English PDF
通常価格
$150.00 USD
通常価格
セール価格
$150.00 USD
単価
/
あたり
配送料はチェックアウト時に計算されます。
受取状況を読み込めませんでした
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click MT 209-1990
Historical versions: MT 209-1990
Preview True-PDF (Reload/Scroll if blank)
MT 209-1990: Electrical and electronic products for coal mine - Communication, testing and control - General technical requirements
MT 209-90 (MT 209-1990)
MT
INDUSTRIAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
MT 209-90
Electrical and electronic products for coal mine
communication, testing and control –
General technical requirements
ISSUED ON. APRIL 4, 1990
IMPLEMENTED ON. DECEMBER 1, 1990
Issued by. National Energy Administration
3. No action is required - Full-copy of this standard will be automatically and
immediately delivered to your EMAIL address in 0~60 minutes.
Table of Contents
1 Subject content and scope of application ... 3
2 Normative references ... 3
3 General provisions ... 5
4 Environmental conditions ... 5
5 Use performance ... 8
6 Appearance ... 11
7 Structure ... 12
8 Electrical clearance and creepage distance ... 13
9 Major components and elements ... 13
10 Temperature rise ... 16
11 Electrical safety ... 16
12 Stability ... 17
13 Explosion-proof performance ... 19
14 Marking ... 19
Annex A Selection of severity level for special environmental conditions
(supplementary) ... 21
Annex B Effect of altitude on product temperature rise and insulation electrical
strength (supplementary) ... 22
Annex C Explosion proof and mining - General products shall be tested
(informative) ... 23
Additional information... 24
Electrical and electronic products for coal mine
communication, testing and control –
General technical requirements
MT 209-90
This Standard is used in conjunction with MT 210 “Electrical and electronic products
for coal mine communication, testing and control - Basic test method” and MT 211
“Electrical and electronic products for coal mine communication, testing and control -
Quality inspection rules”.
1 Subject content and scope of application
1.1 This Standard specifies the basic technical requirements for electrical and
electronic products for coal mine communication, testing and control (hereinafter
referred to as products).
1.2 This Standard applies to.
a. Coal mine communication, signal system and equipment;
b. Monitoring, control, regulating system, equipment and instrumentation for coal
mine infrastructure, production process and environment;
c. Measurement and control equipment and instrumentation for electromechanical
equipment in coal mines.
2 Normative references
GB 156 Rated voltage
GB 190 Label for packages of dangerous goods
GB 191 Packaging - Pictorial markings for handling of goods
GB 762 Standard current
GB 1497 Basic standards for low voltage electrical appliances
GB 2423.1 Basic environmental testing procedures for electrical and electronic
products - Test A. Cold
GB 2423.2 Basic environmental testing procedures for electrical and electronic
products - Test B. Dry heat
GB 2423.3 Basic environmental testing procedures for electrical and electronic
products - Test Ca. Damp heat steady state
GB 2423.4 Basic environmental testing procedures for electrical and electronic
products - Test Db. Damp heat, cyclic
GB 2423.5 Electrical and electronic products - Basic environmental test procedures
- Test Ea. Shock
GB 2423.6 Basic environmental testing procedures for electrical and electronic
products - Test Eb. Bump
GB 2423.10 Basic environmental testing procedures for electrical and electronic
products - Test Fc. Vibration (sinusoidal)
GB 2681 Conductor color in electrical assembly devices
GB 2682 Color of indicator lights and push-buttons used in electrical assembly
devices
GB 3047.1 Basic dimensions of panels, stands and cabinets
GB 3836.1 Electrical apparatus for explosive atmosphere - General requirements
GB 3836.2 Electrical apparatus for explosive atmosphere - Flameproof electrical
apparatus d
GB 3836.3 Electrical apparatus for explosive atmosphere - Increased safety e
GB 3836.4 Electrical apparatus for explosive atmosphere - Intrinsically safe circuits
and electrical apparatus
GB 4588.1 Technical requirements for single and double sided printed boards
without metallized holes
GB 4588.2 Technical requirements for single and double sided printed boards with
metallized holes
GB 4796 Classification of environmental parameters and severity of electrical and
electronic products
GB 4798.1 Electrical and electronic applications - Environmental conditions of use
- Storage
ZBY 120 Industrial automation instrumentation - Operating conditions temperature,
humidity and atmospheric pressure
SJ 2313 Printed circuit board dimension series
MT 154.1 Preparation guidelines and management methods of coal mine
electromechanical products
MT 210 Electrical and electronic products for coal mine communication, testing and
control - Basic test method
standards in accordance with the type of the coal mine communication, testing and
control products, AND shall comply with the relevant provisions of the corresponding
national industry standards.
a. Monitoring, control system and equipment. use functions, transmission distance,
capacity, power supply method, input and output signals, quality indicators (bit
error rate, accuracy or measurement error, etc.), transmission frequency, or
rate;
b. Testing instruments and sensors. use functions, power supply method, output
signal, work system, sensitivity, measurement range, quality indicators
(accuracy or measurement error);
c. Communication system and equipment. use functions, power supply method,
coverage, frequency used, signal method, capacity classification, network
access requirements, voice quality, communication method, transmission
attenuation, and defense.
5.1.5 The sound level of the coal mine underground signal product shall not be less
than 85 dB.
5.2 Voltage and current
5.2.1 The rated voltage shall comply with the provisions of GB 156.
5.2.2 The rated current shall comply with the provisions of GB 762.
5.3 Signal system
5.3.1 General requirements
In the coal mine monitoring and control system, the switching signals and analog
signals of the information transmitted between the substation and the sensor and the
controlled device shall comply with the provisions of this Clause.
5.3.2 Switching value
5.3.2.1 When the output current of the active switch output signal at the high level
output state is 2 mA, the output voltage shall be not less than 3 V; at the low level
output state, when the input current is 2 mA, the output voltage shall be not more than
0.5 V.
5.3.2.2 At the inactive switch output state, when it is disconnected (cut off), the
leakage resistance between the two outputs shall be not less than 100 kΩ; when it is
closed (connected) and the input current is 2 mA, the output end voltage shall be not
more than 0.5 V.
5.3.3 Analog signal
5.3.3.1 DC analog signals shall be.
1 ~ 5 mA (load resistance 0 ~ 500 Ω or greater than 500 Ω).
4 ~ 20 mA (load resistance 0 ~ 350 Ω or greater than 350 Ω).
6.2 Metal parts shall not have corrosion and other mechanical damage.
6.3 The switch button shall be flexible and reliable in operation. The parts shall be
tightened without loosening, AND the plugging moving parts shall be plugged freely.
6.4 The indicator lamps of different functions shall be distinguishable in colors, AND
the function description symbols and texts as well as all product labels shall be clear,
regular, and tightly installed.
6.5 The surface roughness of the flameproof joint face AND the flameproof holes shall
comply with the relevant provisions, AND the surface shall be free form scra...
Get QUOTATION in 1-minute: Click MT 209-1990
Historical versions: MT 209-1990
Preview True-PDF (Reload/Scroll if blank)
MT 209-1990: Electrical and electronic products for coal mine - Communication, testing and control - General technical requirements
MT 209-90 (MT 209-1990)
MT
INDUSTRIAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
MT 209-90
Electrical and electronic products for coal mine
communication, testing and control –
General technical requirements
ISSUED ON. APRIL 4, 1990
IMPLEMENTED ON. DECEMBER 1, 1990
Issued by. National Energy Administration
3. No action is required - Full-copy of this standard will be automatically and
immediately delivered to your EMAIL address in 0~60 minutes.
Table of Contents
1 Subject content and scope of application ... 3
2 Normative references ... 3
3 General provisions ... 5
4 Environmental conditions ... 5
5 Use performance ... 8
6 Appearance ... 11
7 Structure ... 12
8 Electrical clearance and creepage distance ... 13
9 Major components and elements ... 13
10 Temperature rise ... 16
11 Electrical safety ... 16
12 Stability ... 17
13 Explosion-proof performance ... 19
14 Marking ... 19
Annex A Selection of severity level for special environmental conditions
(supplementary) ... 21
Annex B Effect of altitude on product temperature rise and insulation electrical
strength (supplementary) ... 22
Annex C Explosion proof and mining - General products shall be tested
(informative) ... 23
Additional information... 24
Electrical and electronic products for coal mine
communication, testing and control –
General technical requirements
MT 209-90
This Standard is used in conjunction with MT 210 “Electrical and electronic products
for coal mine communication, testing and control - Basic test method” and MT 211
“Electrical and electronic products for coal mine communication, testing and control -
Quality inspection rules”.
1 Subject content and scope of application
1.1 This Standard specifies the basic technical requirements for electrical and
electronic products for coal mine communication, testing and control (hereinafter
referred to as products).
1.2 This Standard applies to.
a. Coal mine communication, signal system and equipment;
b. Monitoring, control, regulating system, equipment and instrumentation for coal
mine infrastructure, production process and environment;
c. Measurement and control equipment and instrumentation for electromechanical
equipment in coal mines.
2 Normative references
GB 156 Rated voltage
GB 190 Label for packages of dangerous goods
GB 191 Packaging - Pictorial markings for handling of goods
GB 762 Standard current
GB 1497 Basic standards for low voltage electrical appliances
GB 2423.1 Basic environmental testing procedures for electrical and electronic
products - Test A. Cold
GB 2423.2 Basic environmental testing procedures for electrical and electronic
products - Test B. Dry heat
GB 2423.3 Basic environmental testing procedures for electrical and electronic
products - Test Ca. Damp heat steady state
GB 2423.4 Basic environmental testing procedures for electrical and electronic
products - Test Db. Damp heat, cyclic
GB 2423.5 Electrical and electronic products - Basic environmental test procedures
- Test Ea. Shock
GB 2423.6 Basic environmental testing procedures for electrical and electronic
products - Test Eb. Bump
GB 2423.10 Basic environmental testing procedures for electrical and electronic
products - Test Fc. Vibration (sinusoidal)
GB 2681 Conductor color in electrical assembly devices
GB 2682 Color of indicator lights and push-buttons used in electrical assembly
devices
GB 3047.1 Basic dimensions of panels, stands and cabinets
GB 3836.1 Electrical apparatus for explosive atmosphere - General requirements
GB 3836.2 Electrical apparatus for explosive atmosphere - Flameproof electrical
apparatus d
GB 3836.3 Electrical apparatus for explosive atmosphere - Increased safety e
GB 3836.4 Electrical apparatus for explosive atmosphere - Intrinsically safe circuits
and electrical apparatus
GB 4588.1 Technical requirements for single and double sided printed boards
without metallized holes
GB 4588.2 Technical requirements for single and double sided printed boards with
metallized holes
GB 4796 Classification of environmental parameters and severity of electrical and
electronic products
GB 4798.1 Electrical and electronic applications - Environmental conditions of use
- Storage
ZBY 120 Industrial automation instrumentation - Operating conditions temperature,
humidity and atmospheric pressure
SJ 2313 Printed circuit board dimension series
MT 154.1 Preparation guidelines and management methods of coal mine
electromechanical products
MT 210 Electrical and electronic products for coal mine communication, testing and
control - Basic test method
standards in accordance with the type of the coal mine communication, testing and
control products, AND shall comply with the relevant provisions of the corresponding
national industry standards.
a. Monitoring, control system and equipment. use functions, transmission distance,
capacity, power supply method, input and output signals, quality indicators (bit
error rate, accuracy or measurement error, etc.), transmission frequency, or
rate;
b. Testing instruments and sensors. use functions, power supply method, output
signal, work system, sensitivity, measurement range, quality indicators
(accuracy or measurement error);
c. Communication system and equipment. use functions, power supply method,
coverage, frequency used, signal method, capacity classification, network
access requirements, voice quality, communication method, transmission
attenuation, and defense.
5.1.5 The sound level of the coal mine underground signal product shall not be less
than 85 dB.
5.2 Voltage and current
5.2.1 The rated voltage shall comply with the provisions of GB 156.
5.2.2 The rated current shall comply with the provisions of GB 762.
5.3 Signal system
5.3.1 General requirements
In the coal mine monitoring and control system, the switching signals and analog
signals of the information transmitted between the substation and the sensor and the
controlled device shall comply with the provisions of this Clause.
5.3.2 Switching value
5.3.2.1 When the output current of the active switch output signal at the high level
output state is 2 mA, the output voltage shall be not less than 3 V; at the low level
output state, when the input current is 2 mA, the output voltage shall be not more than
0.5 V.
5.3.2.2 At the inactive switch output state, when it is disconnected (cut off), the
leakage resistance between the two outputs shall be not less than 100 kΩ; when it is
closed (connected) and the input current is 2 mA, the output end voltage shall be not
more than 0.5 V.
5.3.3 Analog signal
5.3.3.1 DC analog signals shall be.
1 ~ 5 mA (load resistance 0 ~ 500 Ω or greater than 500 Ω).
4 ~ 20 mA (load resistance 0 ~ 350 Ω or greater than 350 Ω).
6.2 Metal parts shall not have corrosion and other mechanical damage.
6.3 The switch button shall be flexible and reliable in operation. The parts shall be
tightened without loosening, AND the plugging moving parts shall be plugged freely.
6.4 The indicator lamps of different functions shall be distinguishable in colors, AND
the function description symbols and texts as well as all product labels shall be clear,
regular, and tightly installed.
6.5 The surface roughness of the flameproof joint face AND the flameproof holes shall
comply with the relevant provisions, AND the surface shall be free form scra...
Share