Skip to product information
1 of 4

PayPal, credit cards. Download editable-PDF and invoice in 1 second!

FZ/T 20018-2010 English PDF (FZT20018-2010)

FZ/T 20018-2010 English PDF (FZT20018-2010)

Regular price $70.00 USD
Regular price Sale price $70.00 USD
Sale Sold out
Shipping calculated at checkout.
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click FZ/T 20018-2010
Historical versions: FZ/T 20018-2010
Preview True-PDF (Reload/Scroll if blank)

FZ/T 20018-2010: Determination of dichloromethane-soluble matter in wool textiles
FZ/T 20018-2010
FZ
TEXTILE INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 59.080.01
W 20
Replacing FZ/T 20018-2000
Determination of dichloromethane-soluble
matter in wool textiles
(ISO 3074.1975, Wool-Determination of dichloromethane-soluble
matter in combed silver, MOD)
ISSUED ON. AUGUST 16, 2010
IMPLEMENTED ON. DECEMBER 01, 2010
Issued by. Ministry of Industry and Information Technology of the
People's Republic of China
Table of Contents
Foreword ... 3 
1. Scope ... 5 
2. Normative references ... 5 
3. Theory ... 5 
4. Reagent ... 5 
5. Instrument ... 6 
6. Sample preparation ... 6 
7. Experimental procedures ... 6 
8. Calculating ... 7 
9. Test report ... 7 
Foreword
This Standard is drafted according to the rules provided in GB/T 1.1-2009.
This Standard replaces FZ/T 20018-2000 Determination of dichloromethane-soluble
matter in wool textiles. Than main differences from FZ/T 20018-2000 are as follows.
─ Modified the English name of the standard;
─ Wool and brocade blending product is added in the scope of Chapter 1;
─ Illustration of reagent is added in Chapter 4 Reagent;
─ Chapter 7 is modified; the experimental procedures are described by steps;
─ 7.6 is modified; weighing balance weight is deleted;
─ Chapter 8 is modified; processing of experimental results is difference;
─ Chapter 9 is modified; name and specification of samples and Date of experiment
are added.
This Standard is modified by adopting ISO 3074.1975 Determination of dichloromethane-
soluble matter in combing wool silver. The main differences from ISO 3074.1975 are as
follows.
─ ISO foreword is deleted;
─ Introduction of ISO is deleted, and it is revised into the scope of standard;
─ Normative reference document is added;
─ Sample mass is modified (see in 6.2);
─ 10.1 extraction formula containing water in ISO is deleted;
─ Name and specification of samples and Date of experiment are added in experimental
report.
This Standard was proposed by China National Textile And Apparel Council.
This Standard shall be under the jurisdiction of Wool-Textile Subcommittee of National
Textile Technical Committee of Standardization Administration of China (SAC/TC 209/SC
3).
Drafting organization of this Standard. Shanghai Wool-Linen Textile Institute of Science
and Technology.
Determination of dichloromethane-soluble
matter in wool textiles
1. Scope
This Standard specifies the method to determine the dichloromethane-soluble matter
content in wool textiles by adopting dichloromethane as extraction reagent.
This Standard applies to the determination of the dichloromethane-soluble matter contents
in pure wools, wool/acrylic or wool/brocade blended combing silver, semi-finished products,
and finished products. For other plush products, it shall also implement this Standard.
2. Normative references
The following document is indispensable for application of this document. For the dated
documents so quoted, only the dated versions apply to this document. For the undated
documents so quoted, the latest versions (including all modification sheets) apply to this
document.
GB/T 8170 Rules of rounding off for numerical values and expression and judgement of
limiting values
3. Theory
Extract the samples in a soxhlet extractor with dichloromethane; evaporate the reagent;
weigh the mass of the remaining matter to calculate the content of dichloromethane soluble
matter, which is the percent of the remaining matter mass in the extracted samples’ drying
mass.
4. Reagent
4.1 Dichloromethane. boiling point is between 39°C ~ 41°C, analytically pure or chemically
pure.
The matter remained after evaporating 100mL of this reagent does not exceed 1mg.
Note. This reagent is toxic and irritates eyes, please take complete protection measure
whining using it. And the operation shall be implemented in fuming cupboard.

View full details