GB/T 37545-2019 English PDF (GBT37545-2019)
GB/T 37545-2019 English PDF (GBT37545-2019)
Regular price
$320.00 USD
Regular price
Sale price
$320.00 USD
Unit price
/
per
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click GB/T 37545-2019
Historical versions: GB/T 37545-2019
Preview True-PDF (Reload/Scroll if blank)
GB/T 37545-2019: Determination of 38 kinds of permitted colorants in cosmetics -- High performance liquid chromatography
GB/T 37545-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 71.100.70
Y 42
GB 37545-2019
Determination of 38 kinds of permitted colorants in
cosmetics - High performance liquid chromatography
ISSUED ON: JUNE 04, 2019
IMPLEMENTED ON: JANUARY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3
Introduction ... 4
1 Scope ... 5
2 Normative references ... 5
3 Principle ... 5
4 Reagents and materials ... 5
5 Instruments and equipment ... 7
6 Sample preparation ... 7
7 Analysis steps ... 8
8 Result calculation ... 12
9 Recovery rate and precision ... 13
10 Tolerance ... 13
Appendix A (Informative) Chinese name, detection concentration, detection limit,
minimum quantitation concentration and quantitation-limit of 38 permitted colorants
... 14
Appendix B (Informative) Information sheet for 38 permitted colorants ... 16
Appendix C (Informative) Liquid chromatographic separation chromatogram of the
standard substances of 38 permitted colorants ... 23
Determination of 38 kinds of permitted colorants in
cosmetics - High performance liquid chromatography
1 Scope
This Standard specifies the principle, reagents and materials, instruments and
equipment, sample preparation, analysis steps, result calculation, recovery rate and
precision, tolerance and other contents for the high performance liquid chromatography
determination of 38 kinds of permitted colorants in cosmetics.
The high performance liquid chromatography specified in this Standard applies to the
quantitative determination of 38 permitted colorants (excluding lakes) in lipsticks, nail
polishes, powders and other cosmetics.
Refer to Table A.1 in Appendix A for the detection-limit and quantitation-limit of the
target of this standard method.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Principle
Use the tetrahydrofuran-methanol-water system to simultaneously extract the water-
soluble and oil-soluble colorants in cosmetics. After centrifuging to remove the base
material, use methanol to redissolve and dilute the extract which has been concentrated
by nitrogen blowing; use the reversed-phase high performance liquid chromatographic
separation, and the standard curve external standard method for quantitation. For
cosmetic samples which are confirmed by high performance liquid chromatography to
be out of range or out of limit in using permitted colorants, mass spectrometry
confirmation shall be taken when necessary.
4 Reagents and materials
Unless otherwise stated, the water used is the grade-1 water specified in GB/T 6682.
4.1 Standard substance: the purity is greater than 90%. See Table B.1 in Appendix B for
the Chinese names, common name of the colorant index, CI number, CAS number,
molecular formula, structural formula, and relative molecular mass of 38 kinds of
permitted colorants.
4.2 Methanol: analytical reagent.
4.3 Methanol: chromatographic pure.
4.4 Formic acid: chromatographic pure.
4.5 Tetrahydrofuran: analytical reagent.
4.6 Dimethyl sulfoxide: analytical reagent.
4.7 Acetonitrile: chromatographic pure.
4.8 Ammonium acetate: analytical reagent.
4.9 Sodium ascorbate: analytical reagent.
4.10 Standard solution diluent: Accurately weigh 0.1 g of sodium ascorbate (4.9); add
5 mL of water to dissolve; continue to add 5 mL of tetrahydrofuran; use methanol (4.3)
to fix volume to 100 mL. (Formulate when needed)
4.11 0.5 mol/L ammonium acetate aqueous solution (containing 0.5% sodium
ascorbate): Accurately weigh 3.85 g of ammonium acetate (4.8) and 0.5 g of sodium
ascorbate (4.9) into a volumetric flask; dissolve in water and dilute to 100 mL.
4.12 0.03 mol/L ammonium acetate aqueous solution (containing 0.075% formic acid):
Accurately weigh 2.31 g of ammonium acetate (4.8); first, add water to dissolve; then,
continue to add 750 μL of formic acid (4.4) that is accurately pipetted; finally, add water
to fix volume to 1 L; shake and mix well for later use.
4.13 Standard stock solution A: Accurately weigh 5 mg (accurate to 0.01 mg) of each
standard substance (Food Red 10, Acid Violet 43, Acid Orange 10, Acid Blue 62, Acid
Yellow 1, Acid Blue 7, Acid Yellow 11, Food Red 9, Food Blue 1, Food Red 7, Food
Yellow 3, Food Red 17, Food Blue 2, Food Green 3 and Food Blue 5, 15 kinds in total)
in the brown volumetric flasks, respectively; dissolve in water and fix volume to 10 mL,
to prepare into standard stock solutions with a mass concentration of 500 μg/mL; store
in the dark at 4 °C ~ 6 °C; the storage period is 3 months.
4.14 Standard stock solution B: Accurately weigh 5 mg (accurate to 0.01 mg) of each
standard substance (Acid Red 88, Bromocresol Green, Basic Violet 2, Acid Orange 7,
Acid Red 50, Acid Violet 9, Acid Green 9, Acid Black 1, Acid Red 52. Acid Blue 1,
Acid Yellow 121, Disperse Yellow 16, Basic Blue 26, Acid Red 98, Solvent Yellow 29,
Acid Violet 50, Acid Green 22, 17 kinds in total) in the brown volumetric flasks,
respectively; dissolve in methanol (4.3) and dilute to 10 mL, to prepare into standard
stock solutions with a mass concentration of 500 μg/mL; store in the dark at 4 °C ~ 6 °C;
the storage period is 3 months.
4.15 Standard stock solution C: Accurately weigh 5 mg (accurate to 0.01 mg) of each
standard substance (Solvent Red 3, Solvent Yellow 33 and Solvent Green 3, 3 kinds in
total) in the brown volumetric flasks, respectively; dissolve in tetrahydrofuran and fix
volume to 10 mL, to prepare into standard stock solutions with a mass concentration of
500 μg/mL; store in the dark at 4 °C ~ 6 °C; the storage period is 3 months.
4.16 Standard stock solution D: Accurately weigh 5 mg (accurate to 0.01 mg) of the
standard substance (Pigment Red 4, 1 kind in total) in a brown volumetric flask;
dissolve in tetrahydrofuran and dilute to 10 mL, to prepare into a standard stock solution
with a mass concentration of 500 μg/mL; store in the dark at 4 °C ~ 6 °C; the storage
period is 3 months.
4.17 Standard stock solution E: Accurately weigh 5 mg (accurate to 0.01 mg) of each
standard substance (Pigment Red 49 and Pigment Red 64, 2 kinds in total) in the brown
volumetric flasks, respectively; dissolve in dimethyl sulfoxide and dilute to 10 mL, to
prepare into standard stock solutions with a mass concentration of 500 μg/mL; store in
the dark at 4 °C ~ 6 °C; the storage period is 3 months.
4.18 0.45 μm microporous polytetrafluoroethylene (PTFE) filter membrane needle filter.
5 Instruments and equipment
5.1 High performance liquid chromatography - diode array detector.
5.2 High performance liquid chromatography tandem quadrupole mass spectrometer,
equipped with electrospray ionization source (ESI) (used for qualitative confirmation).
5.3 Analytical balance: sensitivity of 0.001 g, 0.000 01 g.
5.4 Vortex mixer.
5.5 Ultrasonic cleaner: the power is not less than 300 W.
5.6 Centrifuge: the rotation speed is not less than 5 000 r/min, and the capacity of the
centrifugal test tube is 10 mL.
5.7 Pipette or pipettor.
6 Sample preparation
Accurately weigh 0.2 g (accurate to ...
Get QUOTATION in 1-minute: Click GB/T 37545-2019
Historical versions: GB/T 37545-2019
Preview True-PDF (Reload/Scroll if blank)
GB/T 37545-2019: Determination of 38 kinds of permitted colorants in cosmetics -- High performance liquid chromatography
GB/T 37545-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 71.100.70
Y 42
GB 37545-2019
Determination of 38 kinds of permitted colorants in
cosmetics - High performance liquid chromatography
ISSUED ON: JUNE 04, 2019
IMPLEMENTED ON: JANUARY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3
Introduction ... 4
1 Scope ... 5
2 Normative references ... 5
3 Principle ... 5
4 Reagents and materials ... 5
5 Instruments and equipment ... 7
6 Sample preparation ... 7
7 Analysis steps ... 8
8 Result calculation ... 12
9 Recovery rate and precision ... 13
10 Tolerance ... 13
Appendix A (Informative) Chinese name, detection concentration, detection limit,
minimum quantitation concentration and quantitation-limit of 38 permitted colorants
... 14
Appendix B (Informative) Information sheet for 38 permitted colorants ... 16
Appendix C (Informative) Liquid chromatographic separation chromatogram of the
standard substances of 38 permitted colorants ... 23
Determination of 38 kinds of permitted colorants in
cosmetics - High performance liquid chromatography
1 Scope
This Standard specifies the principle, reagents and materials, instruments and
equipment, sample preparation, analysis steps, result calculation, recovery rate and
precision, tolerance and other contents for the high performance liquid chromatography
determination of 38 kinds of permitted colorants in cosmetics.
The high performance liquid chromatography specified in this Standard applies to the
quantitative determination of 38 permitted colorants (excluding lakes) in lipsticks, nail
polishes, powders and other cosmetics.
Refer to Table A.1 in Appendix A for the detection-limit and quantitation-limit of the
target of this standard method.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Principle
Use the tetrahydrofuran-methanol-water system to simultaneously extract the water-
soluble and oil-soluble colorants in cosmetics. After centrifuging to remove the base
material, use methanol to redissolve and dilute the extract which has been concentrated
by nitrogen blowing; use the reversed-phase high performance liquid chromatographic
separation, and the standard curve external standard method for quantitation. For
cosmetic samples which are confirmed by high performance liquid chromatography to
be out of range or out of limit in using permitted colorants, mass spectrometry
confirmation shall be taken when necessary.
4 Reagents and materials
Unless otherwise stated, the water used is the grade-1 water specified in GB/T 6682.
4.1 Standard substance: the purity is greater than 90%. See Table B.1 in Appendix B for
the Chinese names, common name of the colorant index, CI number, CAS number,
molecular formula, structural formula, and relative molecular mass of 38 kinds of
permitted colorants.
4.2 Methanol: analytical reagent.
4.3 Methanol: chromatographic pure.
4.4 Formic acid: chromatographic pure.
4.5 Tetrahydrofuran: analytical reagent.
4.6 Dimethyl sulfoxide: analytical reagent.
4.7 Acetonitrile: chromatographic pure.
4.8 Ammonium acetate: analytical reagent.
4.9 Sodium ascorbate: analytical reagent.
4.10 Standard solution diluent: Accurately weigh 0.1 g of sodium ascorbate (4.9); add
5 mL of water to dissolve; continue to add 5 mL of tetrahydrofuran; use methanol (4.3)
to fix volume to 100 mL. (Formulate when needed)
4.11 0.5 mol/L ammonium acetate aqueous solution (containing 0.5% sodium
ascorbate): Accurately weigh 3.85 g of ammonium acetate (4.8) and 0.5 g of sodium
ascorbate (4.9) into a volumetric flask; dissolve in water and dilute to 100 mL.
4.12 0.03 mol/L ammonium acetate aqueous solution (containing 0.075% formic acid):
Accurately weigh 2.31 g of ammonium acetate (4.8); first, add water to dissolve; then,
continue to add 750 μL of formic acid (4.4) that is accurately pipetted; finally, add water
to fix volume to 1 L; shake and mix well for later use.
4.13 Standard stock solution A: Accurately weigh 5 mg (accurate to 0.01 mg) of each
standard substance (Food Red 10, Acid Violet 43, Acid Orange 10, Acid Blue 62, Acid
Yellow 1, Acid Blue 7, Acid Yellow 11, Food Red 9, Food Blue 1, Food Red 7, Food
Yellow 3, Food Red 17, Food Blue 2, Food Green 3 and Food Blue 5, 15 kinds in total)
in the brown volumetric flasks, respectively; dissolve in water and fix volume to 10 mL,
to prepare into standard stock solutions with a mass concentration of 500 μg/mL; store
in the dark at 4 °C ~ 6 °C; the storage period is 3 months.
4.14 Standard stock solution B: Accurately weigh 5 mg (accurate to 0.01 mg) of each
standard substance (Acid Red 88, Bromocresol Green, Basic Violet 2, Acid Orange 7,
Acid Red 50, Acid Violet 9, Acid Green 9, Acid Black 1, Acid Red 52. Acid Blue 1,
Acid Yellow 121, Disperse Yellow 16, Basic Blue 26, Acid Red 98, Solvent Yellow 29,
Acid Violet 50, Acid Green 22, 17 kinds in total) in the brown volumetric flasks,
respectively; dissolve in methanol (4.3) and dilute to 10 mL, to prepare into standard
stock solutions with a mass concentration of 500 μg/mL; store in the dark at 4 °C ~ 6 °C;
the storage period is 3 months.
4.15 Standard stock solution C: Accurately weigh 5 mg (accurate to 0.01 mg) of each
standard substance (Solvent Red 3, Solvent Yellow 33 and Solvent Green 3, 3 kinds in
total) in the brown volumetric flasks, respectively; dissolve in tetrahydrofuran and fix
volume to 10 mL, to prepare into standard stock solutions with a mass concentration of
500 μg/mL; store in the dark at 4 °C ~ 6 °C; the storage period is 3 months.
4.16 Standard stock solution D: Accurately weigh 5 mg (accurate to 0.01 mg) of the
standard substance (Pigment Red 4, 1 kind in total) in a brown volumetric flask;
dissolve in tetrahydrofuran and dilute to 10 mL, to prepare into a standard stock solution
with a mass concentration of 500 μg/mL; store in the dark at 4 °C ~ 6 °C; the storage
period is 3 months.
4.17 Standard stock solution E: Accurately weigh 5 mg (accurate to 0.01 mg) of each
standard substance (Pigment Red 49 and Pigment Red 64, 2 kinds in total) in the brown
volumetric flasks, respectively; dissolve in dimethyl sulfoxide and dilute to 10 mL, to
prepare into standard stock solutions with a mass concentration of 500 μg/mL; store in
the dark at 4 °C ~ 6 °C; the storage period is 3 months.
4.18 0.45 μm microporous polytetrafluoroethylene (PTFE) filter membrane needle filter.
5 Instruments and equipment
5.1 High performance liquid chromatography - diode array detector.
5.2 High performance liquid chromatography tandem quadrupole mass spectrometer,
equipped with electrospray ionization source (ESI) (used for qualitative confirmation).
5.3 Analytical balance: sensitivity of 0.001 g, 0.000 01 g.
5.4 Vortex mixer.
5.5 Ultrasonic cleaner: the power is not less than 300 W.
5.6 Centrifuge: the rotation speed is not less than 5 000 r/min, and the capacity of the
centrifugal test tube is 10 mL.
5.7 Pipette or pipettor.
6 Sample preparation
Accurately weigh 0.2 g (accurate to ...