LY/T 3236-2020: Grading and evaluation methods for odor of wood-based panels and its products
LY/T 3236-2020
LY
FORESTRY INDUSTRY STANDARD
ICS 79.080
CCS B 70
Grading and evaluation methods for odor of wood-based
panels and its products
ISSUED ON. DECEMBER 29, 2020
IMPLEMENTED ON. JUNE 01, 2021
Issued by. National Forestry and Grassland Administration
Table of Contents
Foreword... 3
1 Scope... 4
2 Normative references... 4
3 Terms and definitions... 4
4 Test apparatuses... 4
5 Testing room environment... 6
6 Evaluator... 6
7 Test piece preparation... 7
8 Test methods... 8
9 Odor grading... 9
10 Test report... 9
Grading and evaluation methods for odor of wood-based
panels and its products
1 Scope
This document specifies the terms and definitions, test apparatuses, testing room
environment, evaluator, test piece preparation, test method, odor grading and inspection
report of grading and evaluation methods for odor of wood-based panels and its
products.
This document applies to wood-based panels and its products, including plain wood-
based panels, decorated wood-based panels, wooden floors, wooden wall panels,
wooden doors and wood-based panel products.
2 Normative references
The following documents are referred to in the text in such a way that some or all of
their content constitutes requirements of this document. For dated references, only the
dated version applies to this document; for undated references, the latest edition
(including all amendments) applies to this document.
GB/T 11414-2007, Laboratory glassware - Bottles
GB/T 15723-1995, Laboratory glassware - Desiccator
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
odor
The smell given off by a substance.
4 Test apparatuses
4.1 Wide-mouth glass bottle
It shall comply with the requirements of GB/T 11414-2007, with a volume of 2 500 mL,
a sealed lid that is easy to open and close, and no odor at the temperatures of (20±2) °C
4.3 Oven
Temperature can be maintained at (65±2) °C.
4.4 Constant temperature and humidity chamber
Temperature ranges within 10 °C ~ 80 °C, with an accuracy ±2 °C; relative humidity
ranges within 10% ~ 95%, with an accuracy of ±5%.
5 Testing room environment
The testing room shall be fully ventilated, and the temperature shall be controlled at
(20±2) °C. During testing, the indoor environment of the testing room shall be kept
quiet, without interference and without odor.
6 Evaluator
6.1 Selection of evaluators
6.1.1 The evaluators shall have no olfactory defects, no habits such as smoking, using
heavily scented cosmetics, or chewing gum, etc. that affect the olfactory evaluation
ability, and shall have relatively keen sense organs and identification abilities. Before
starting the evaluation, identification tests shall be conducted to select individuals with
better sensory sensitivity.
6.1.2 Prepare 4 samples of isoamyl acetate aqueous solution with the same volume and
different concentrations (5 mg/kg, 10 mg/kg, 20 mg/kg and 40 mg/kg).
6.1.3 Provide 4 samples of isoamyl acetate aqueous solution to candidate evaluators in
random order, and require the candidate evaluators to sort the solution samples in the
order of increasing concentration. Samples shall be provided to all candidate evaluators
in the same order to ensure the comparability of the ranking results from the candidate
evaluators and avoid the impact caused by the different order of supply.
6.1.4 Candidate evaluators who can correctly arrange 4 samples of isoamyl acetate
aqueous solution in the order of increasing concentration can be selected as evaluators
for the odor of wood-based panels and its products. Candidate evaluators who arrange
one or more of the four samples of isoamyl acetate aqueous solution in the wrong
concentration order will be considered unsuitable as evaluators for the odor of wood-
based panels and their products.
6.2 Requirements of evaluators
6.2.1 The evaluation team shall consist of an odd number of 3 or more members.
6.2.2 On the day of the test, odor evaluators shall not carry or use odorous spices,
cosmetics or skin care products that may affect the olfactory evaluation ability, and shall
not eat foods with pungent odors. Odor evaluators who are suffering from colds or
olfactory organ discomfort shall not participate in the measurement on that day.
7 Test piece preparation
7.1 Plain wood-based panels
For plywood, particleboard, fiberboard, block board, glued-laminated timber and other
plain wood-based panels, an edge of (20±0.5) mm shall be removed, and then the test
piece shall be prepared from any part. The specification of the test piece is (25±0.5)
mm × (25 ±0.5) mm × panel thickness, and the total weight of the test piece is (200±10)
g.
7.2 Decorated wood-based panels
For decorated wood-based panels, an edge of (20±0.5) mm shall be removed, and then
the test piece shall be prepared from any part of the panel. The specification of the test
piece is (150±0.5) mm × (150±0.5) mm × panel thickness, and the four sides are sealed
with odorless aluminum foil. When the panel thickness is less than or equal to 30 mm,
the number of test pieces is 10; when the panel thickness is greater than 30 mm, the
number of test pieces is 8.
7.3 Wooden floors
For wooden floors, the test piece shall be prepared after removing the tongue and
groove. The specification of the test piece is (150±0.5) mm × (150±0.5) mm × floor
thickness, and the four sides are sealed with odorless aluminum foil. If the wooden floor
sample is not wide enough, it can be spliced. The number of test pieces is 10.
7.4 Wooden wall panels
For wooden wall panels containing tongues and grooves, the test piece shall be prepared
after removing the tongues and grooves. For wooden wall panels without tongues and
grooves, an edge of (20±0.5) mm shall be removed and then the test piece shall be
prepared from any part of the wooden wall panel. The specification of the test piece is
(150±0.5) mm × (150±0.5) mm × wall panel thickness, and the four sides are sealed
with odorless aluminum foil. If the wooden wall panel sample is not wide enough, it
can be spliced. The number of test pieces is 10.
7.5 Wooden doors
Prepare test pieces from the four corners and edges of the wooden door. The
specification of the test piece is (150±0.5) mm × (150±0.5) mm × door thickness, the
sawn edges are sealed with odorless aluminum foil. It shall be ensured that at least 4
test pieces are taken from the four corners, and the remaining test pieces can be taken
from the edges (retaining the door edges). The number of test pieces is 8.
7.6 Wood-based panel products
Prepare a test piece from the edge-sealed corner of the wood-based panel product. The
specification of the test piece is (150±0.5) mm × (150±0.5) mm × panel thickness. If
the sample size is not enough, multiple samples can be sawed and cut to form one test
piece. Seal the sawn edges with odorless aluminum foil. When the panel thickness is
less than or equal to 30 mm, the number of test pieces is 10; when the panel thickness
is greater than 30 mm, the number of test pieces is 8.
8 Test methods
8.1 Pretreatment of test pieces
Before the test, place the test pieces in an odorless environment with a temperature of
(20±2) °C and a relative humidity of (65±5) %, and adjust for 72 h ± 5 min.
8.2 Test steps
8.2.1 Plain wood-based panels
1) The wide-mouth glass bottle for testing and its lid shall be cleaned and d...